▲▼◄►: navigates between targets.

d)LS :

The sensitivity of comparing two different images. The smaller the value is, the higher sensitivity for motion detection.

The highest sensitivity setting is 00, the lowest sensitivity setting is 15. The default value is 07.

e)SS :

The sensitivity towards the size of the triggered object on the screen.(the number of motion detection grids). The smaller the value is, the higher sensitivity for motion detection.

The highest sensitivity setting is 00, and the lowest sensitivity setting is 15. The default setting is 03.

Note: The default setting of Spatial Sensitivity is 03, which means when 3 grids are detected for motion at one time, the system will get triggered. So the value of Spatial Sensitivity must be less than the number of grids which you set up to motion detection area.

f)TS :

The sensitivity towards how long the object gets triggered. The smaller the value is, the higher sensitivity for motion detection.

The highest sensitivity setting is 00, and the lowest sensitivity setting is 15. The default setting is 02.

g)RE :

The value of RE is a reference for detection. The default value is 10, which means DVR will compare 10 continuous images at one time according to the sensitivity of LS, SS, TS simultaneously. Therefore the bigger the value is, the higher sensitivity for motion detection.

h)ALARM:

Select LOW / HIGH for the alarm polarity. The default alarm value is OFF.

i)PRE / NEXT:

Select “PRE” to go to the previous page; Select “NEXT” to go the next page. Targets set in the AREA.

2)DETECTION TIMER:

Set the date, start time, end time of the detection function.

DETECTION TIMER

DATE

START

 

END

OFF

00

: 00

-

00

: 00

DAILY

08

: 00

-

18

: 00

SUN

06

: 00

-

23

: 00

MON-FRI

00

: 00

-

00

: 00

OFF

00

: 00

-

00

: 00

OFF

00

: 00

-

00

: 00

OFF

00

: 00

-

00

: 00

20