Battery

CAUTION:

Never over fill the battery with water above the upper limit.

The battery contains acids that can cause injury to the eyes and skin.To avoid eye irritation, always wear safety glasses. Use well insulated gloves when picking up the battery. Use the following guidelines when handling the battery:

1.DO NOT drop the battery. There is the possibility the battery may explode.

2.DO NOT expose the battery to open flames, sparks, cigarettes etc. The battery contains combustible gases and liquids. If these gases and liquids come in contact with a flame or spark, an explosion could occur.

3.Always keep the battery charged. If the battery is not charged, a buildup of combustible gas will occur.

4.Always keep battery charging and booster cables in good working condition. Repair or replace all worn cables.

5.Always recharge the battery in an open air environment, to avoid risk of a dangerous concentration of combustible gases.

6.In case the battery liquid (dilute sulfuric acid) comes in contact with clothing or skin, rinse skin or clothing immediately with plenty of water.

7.In case the battery liquid (dilute sulfuric acid) comes in contact with your eyes, rinse eyes immediately with plenty of water, then contact the nearest doctor or hospital, and seek medical attention.

Table of Contents

RULES FOR SAFE OPERATION

NEVER Run engine without an air filter. Severe engine damage may occur.

Always service air cleaner frequently to prevent carburetor malfunction.

Always disconnect the battery before performing service on the generator.

Always be sure the operator is familiar with proper safety precautions and operations techniques before using generator.

Always store equipment properly when not in use. Equipment should be stored in a clean, dry location out of the reach of children.

DO NOT leave the generator running in the manual mode unattended.

DO NOT allow unauthorized people to operate this equipment.

Always read, understand, and follow procedures in Operator’s Manual before attempting to operate equipment.

Refer to the Komatsu Engine Owner's Manualfor engine technical questions or information.

Loading and Unloading (Crane)

Before lifting, make sure the generator's lifting hook is secure and that there is no apparent damage to the generator itself (loose screws, nuts and bolts). If any part is loose or damaged, please take corrective action before lifting.

Always drain fuel prior to lifting.

Always make sure crane or lifting device has been properly secured to the hook of guard frame on generator.

NEVER lift the machine while the engine is running.

Use adequate lifting cable (wire or rope) of sufficient strength.

When lifting the generator, always use the balanced center-point suspension hook and lift straight upwards.

NEVER allow any person or animal to stand underneath the machine while lifting.

When loading the generator on a truck, be sure to use the front and back frame bars as a means to secure the generator during transport.

PAGE 8 —DCA-150SSKII— PARTS AND OPERATION MANUAL — REV. #2 (05/08/01)

Page 8
Image 8
Multiquip DCA-150SSKII operation manual Battery, Loading and Unloading Crane

DCA-150SSKII specifications

The Multiquip DCA-150SSKII is a robust and reliable 150kVA diesel generator designed to meet the demands of various applications, particularly in construction, events, and industrial settings. Engineered for high performance and durability, this generator stands out with its advanced features, technologies, and characteristics.

One of the primary features of the DCA-150SSKII is its powerful Yanmar diesel engine. This engine is renowned for its exceptional fuel efficiency and reliability, ensuring that the generator can run for extended periods without the need for frequent refueling. The engine is designed to meet stringent emissions standards, making the DCA-150SSKII an environmentally friendly option for those needing portable power solutions.

The generator is equipped with a state-of-the-art digital control panel that simplifies the operation and monitoring of the unit. The control panel provides real-time data about the generator's performance, including voltage, frequency, and operational hours, allowing users to efficiently manage power distribution. Additionally, the generator features an automatic voltage regulator that ensures stable and consistent power output, crucial for sensitive electronics and equipment.

The DCA-150SSKII is designed with durability in mind. Its sturdy frame and weather-resistant enclosure protect it from the elements, making it suitable for outdoor use in a variety of conditions. Noise reduction technology is integrated into the design, ensuring that the generator operates quietly, which is particularly beneficial for urban settings or nighttime operations.

Safety is paramount in the design of the DCA-150SSKII. It includes essential safety features such as low oil pressure shutdown, high-temperature shutdown, and overload protection. These features help prevent damage to the generator and ensure safe operation in various environments.

Mobility is another characteristic that sets the DCA-150SSKII apart. It is equipped with a robust chassis and lifting hooks, making it easy to transport from one location to another, whether on a job site or for an event.

In summary, the Multiquip DCA-150SSKII combines power, efficiency, and reliability in a compact design. Its advanced technological features, durability, and safety mechanisms make it an excellent choice for anyone in need of a dependable diesel generator. With its powerful performance and user-friendly operation, the DCA-150SSKII is a top contender in the generator market, meeting the diverse power needs of professionals across various industries.