Practically all breakdowns can be prevented by proper handling and maintenance inspections, but in the event of a breakdown, use the tables shown for

diagnosis based on the Engine and Radiator Troubleshooting (Table 18) and the MPEC Troubleshooting (Table 19). If the problem cannot be remedied, consult our company's business office or service plant.

TABLE 18. ENGINE & GENERATOR TROUBLESHOOTING

SYMPTOM

POSSIBLE PROBLEM

SOLUTION

 

 

 

 

Dead battery?

Replace battery.

Engine fails to start and

 

 

Defective starter switch?

Replace switch.

starter does not rotated.

 

 

 

Fuse F5 burned out?

Replace fuse.

 

 

 

 

Broken pre-heat circuit?

Check pre-heat circuit.

Engine fails to start and

 

 

No fuel?

Add fuel.

starter rotates.

 

 

 

Defective wiring?

Check wiring.

 

 

 

 

Clogged fuel strainer?

Clean or replace.

Engine starts and remains at

 

 

Clogged air cleaner?

Clean or replace.

low speed.

 

 

 

Disconnected wiring?

Check and repair wiring.

 

 

 

 

No voltage present in AC

Replace rectifier (RE1).

 

power source?

 

 

 

 

 

Engine speed rises and no

Defective rotor?

Replace rotor.

 

 

 

 

volteage is present n AC

Defective voltmeter?

Replace voltmeter.

power source.

 

 

Disconnected wiring?

Check and repair wiring.

 

 

 

 

 

Layer short-circuit in armature

Replace armature.

 

winding?

 

 

 

 

 

Engine speed rises and AC

Defective circuit breaker

Replace circuit breaker (protector).

(protector)?

 

power voltage is too low or

 

 

Layer short-circuit, broken

 

cannot be used.

Repair or replace armature.

 

wires in armature winding?

 

 

 

 

 

Engine speed rises and

Defective engine regulator?

Replace regulator.

 

 

battery discharges too soon.

Defective wiring?

Repair or replace wiring.

 

 

 

Engine speed rises and

Defective alternator?

Repair or replace alternator.

 

 

engine seems overloaded.

Damaged alternator bearing?

Replace alternator bearings.

 

 

 

 