DCA-150SSKII — OUTPUT TERMINAL PANEL OVERVIEW

Table of Contents

DCA-150SSKII — OUTPUT TERMINAL PANEL OVERVIEW

How to read the output terminal guages.

The guages and knobs on the control panel DO NOT effect the generator output in any fashion. They are there to simply help the operator observe how much power is being supplied produced at the UVWO legs.

When the voltage selector switch is in the 240/120V position (see figure 15), place the AC Voltmeter Change- over switch to the W-U position and the AC ammeter Change-over Switch to the U or W position to read the

output on the selected leg.

FIGURE 18. AC AmmeterFIGURE 19. ACAmmeter

 

Change-over Switch(Amp reading on U lug)

 

(Reading the U leg on the

 

 

output terminal panel)

 

NOTE

When using plural single phase voltages, make sure to balance the load on each of the single phase legs.

FIGURE 15. Voltage Selector Switch 240/120V Single Phase

Position

FIGURE 16. AC Voltmeter

Change-over switch

(Reading the W-U leg on the outputerminal panel)
FIGURE 17. AC Voltmeter

Guage

(Volt reading on W-U Lug)