Multiquip DCA-150SSKII Battery Cable Installation, Wiring, Piping and Hose Connection

Models: DCA-150SSKII

1 92
Download 92 pages 7.3 Kb
Page 45
Image 45
Battery Cable Installation

Battery Cable Installation

ALWAYS be sure the battery cables (Figure 41) are properly connected to the battery terminals as shown below. The RED cable is connected to the positive terminal of the battery, and the BLACK cable is connected to the negative terminal of the battery.

Figure 41. Battery Connections

CAUTION :

If the battery cable is connected incorrectly, electrical damage to the generator will occur. Pay close attention to the polarity of the battery when connecting the battery.

When connecting battery do the following:

1.ALWAYS make sure that the Off/Manual/Auto switch is in the "OFF" position when connecting the battery. If the generator is equipped with an ignition switch, make sure the ignition switch is in the "OFF" postion and the key is removed.

2.Place a small amount of grease around both battery terminals. This will ensure a good connection and will help prevent corrosion around the battery terminals.

Table of Contents

DCA-150SSKIIPRE-SETUP

CAUTION :

Inadequate battery connections may cause poor starting of the generator, and create other malfunctions.

Wiring

Inspect the entire generator for bad or worn electrical wiring or connections. If any wiring or connections are exposed (insulation missing) replace wiring immediately.

Piping and Hose Connection

Inspect all piping, oil hose, and fuel hose connections for wear and tightness.Tighten all hose clamps and check hoses for leaks.

If any hose (fuel or oil) lines are defective replace them immediately.