Multiquip GAC-9.7HZ Fuel Check, Battery Check, Oil Type, Season, Inspection/Setup, Temperature

Models: GAC-9.7HZ

1 88
Download 88 pages 8.18 Kb
Page 21
Image 21
Table 4. Oil Type

INSPECTION/SETUP

Table 4. Oil Type

Season

Temperature

Oil Type

Summer

25°C or Higher

SAE 10W-30

Spring/Fall

25°C~10°C

SAE 10W-30/20

Winter

0°C or Lower

SAE 10W-10

Fuel Check

1.Close the fuel cock before filling the fuel tank.

2.Remove the fuel cap located on top of fuel tank.

3.Read the fuel gauge located on top of the fuel tank (Figure 9) to determin if the fuel level is low. If fuel is low, replenish with clean unleaded fuel.

Figure 9. Fuel Gauge

4.When refueling, be sure to use a strainer for filtration. DO NOT top-off fuel. DO NOT fill the tank beyond capacity. Wipe up any spilled fuel immediately!

Battery Check

ALWAYS be sure the battery cables (Figure 10) are properly connected to the battery terminals as shown below. The red cable is connected to the positive terminal of the battery, and the black cable is connected to the negative terminal of the battery.

Figure 10. Battery Connections

GAC9.7HZ 60 hz GENERATOR • operation and parts manual — rev. #2 (03/31/10) — page 21