operation/shutdown

NOTICE

When using a combination of dual receptacles, total load should not exceed the rated capacity of the generator.

16.The L14-30R receptacle is a dual voltage receptacle (120-240 volts). Reference Figures 23 and 24 to verify voltages at this receptacle.

Figure 23. 120/240V Receptacle (120V)

Figure 24. 120/240V Receptacle (240V)

17.Connecting of loads (power tools, lighting ect.) to the generator receptacles can now be done.

Stopping the Engine (Normal Shutdown)

1.Place main circuit breaker (Figure 25) in the OFF position.

Figure 25. Main Circuit Breaker (OFF)

2.Place GFCI and AUX. circuit breakers (Figure 26) in the OFF positing.

Figure 26. GFCI/AUX. Circuit Breakers (OFF)

3. Place idle control switch (Figure 27) in the OFF position.

Figure 27. Idle Control switch (OFF)

4.Let engine run at idle with no load for 2-3 minutes.

5.To shut-down the engine, place the generator's operation switch (Figure 28) in the OFF position).

Figure 28. Operation Switch (OFF)

6.Remove all loads from the generator.

Emergency Shutdown

1. Place operation switch (Figure 28) in the OFF position.