Multiquip HTXD6i / STXD6i manual General Procedures, Setup Jumper Installation

Models: HTXD6i / STXD6i

1 32
Download 32 pages 25.91 Kb
Page 12
Image 12

GENERAL PROCEDURES

NOTICE

These general procedures will be referenced in other sections throughout the manual.

SETUP JUMPER INSTALLATION

NOTICE

Machine must be secured prior to installation. Installing setup jumper will:

Disable Cold Start

Increase Engine RPM to Full operating RPM

Disable Stroke Follower

1.Remove Cap (P\N: 22812) on P24 of main harness (under foot platform).

2.Install Setup Jumper (P/N: 32007 on P24).

REMOVE SETUP JUMPER (If installed).

1.Remove Setup Jumper (P\N: 32007) from P24 of main harness.

2.Re-install Cap (P\N: 22812) on P24 of main harness.

Table 2. Disable and Re-enable Options

 

 

1.

Open service tool.

 

 

2.

Click “machine setup” button on main page.

 

Cold Start

3.

Click “Cold Start” button under Setup Menu.

DISABLE

 

4.

Click check box next to Disabled.

(If Setup Jumper is not

 

5.

Press Download Button.

installed)

 

1.

Open service tool.

 

Stroke Follower

2.

Click “machine setup” button on main page.

 

3.

Click “Stroke Cont.” button under Setup Menu.

 

 

 

 

4.

Click button “Disable Stroke Follower”.

 

 

1.

Open service tool.

 

 

2.

Click “machine setup” button on main page.

 

Cold Start

3.

Click “Cold Start” button under Setup Menu.

RE-ENABLE

 

4.

Uncheck box next to Disable.

 

 

 

 

(If disabled via service

 

5.

Press Download Button.

tool)

 

1.

Open service tool.

 

Stroke Follower

2.

Click “machine setup” button on main page.

 

3.

Click “Stroke Cont.” button under Setup Menu.

 

 

 

 

4.

Click button “Enable Stroke Follower”.

PAGE 12 — HTXD6i/STXD6i TROWEL • SETUP, ADJUSTMENTS AND CALIBRATIONS — REV. #1 (01/24/14)

Page 12
Image 12
Multiquip HTXD6i / STXD6i manual General Procedures, Setup Jumper Installation, Remove Setup Jumper If installed