MACHINE SETUP AND CALIBRATION

5.Re-measure speed, repeating steps 2 and 3 until Left Side Trowel Speed is correct:

a.HTXD6i — 157 to 160 RPM (942 to 960 Pulses per minute)

b.STXD6i— 127 to 130 RPM (762 to 780 Pulses per minute)

6.Record L.H. speed on Machine Information and Maintenance Log in machine setup area.

Right Side Trowel Speed Adjustment

NOTICE

Stroke sensor must be recalibrated after trowel speed adjustment for proper machine operation.

The trowel speeds should be adjusted on a dry concrete floor with the blades pitched slightly (tips about 1/2” off ground).

1.Verify setup jumper is installed or stroke follower is disabled.

2.Fully depress pedal, measure Left Side and Right Side Trowel Speed.

3.Adjust trowel arm connecting rod on the pump actuating lever and tighten jamb nuts (Figure 33).

Calibrate Stroke Sensor

CAUTION

Machine movement will occur during this step. Ensure machine is secure or operator is present in seat. All guards should be in place. Keep fingers, hands, hair, and clothing away from all moving parts to prevent injury.

1.Turn machine off for at least 10 seconds.

2.Restart machine.

3.Install Setup Jumper or disable Stroke Follower.

4.Click “Calibration” button on machine setup page.

5.Click “Calibration” button in STROKE SENSOR section (Figure 34).

Figure 34. Calibrate Stroke Sensor

Figure 33. Adjusting Right Side Trowel Speed

4.Re-measure speed and repeat steps 2 and 3 until Left Side and Right side are within 1 RPM of each other.

5.Record R.H. speed on Machine Information and Maintenance Log in Machine Setup section.

6.Remove setup jumper or re-enable stroke follower.

HTXD6i/STXD6i TROWEL • SETUP, ADJUSTMENTS AND CALIBRATIONS — REV. #1 (01/24/14) — PAGE 23