ST-45HRM CE CONCRETE PUMP— INSPECTION
CAUTION
NEVER operate the pump in a confined area or enclosed area structure that does not provide ample free flow of air.
ALWAYS wear approved eye and hearing protection before operating the pump .
NEVER place hands or feet inside the hopper. ALWAYS shut- down the engine before performing any kind of maintenance on the pump.
NEVER operate the pumps's engine with the engine hood or
FUEL CHECK
5.Read the fuel sight tube (Figure 10) on top of the fuel tank to determine if the pump's engine fuel is low .
Reference Figures 7 through 9 for
NOTE the location of any control or component referenced in this section.
Before Starting
1.Read safety instructions at the begin- ning of manual.
2.Clean the entire pump, removing dirt and dust, particularly the engine cooling air inlet, and air filter.
3.Check theairfilter for dirtanddust. Ifairfilterisdirty,replace air filter with a new one as required.
4.Check fastening nuts and bolts for tightness.
CAUTION:
Handle fuel safely. Diesel fuel is highly flammable and can be dangerous if mishandled. DO NOT smoke while refueling. DO NOT attempt to refuel mixer if the engine is hot or running. ALWAYS allow engine to cool before refueling.
Figure 10. Fuel Sight Tube
6.If fuel is low, remove fuel filler cap and fill with #2 diesel fuel (Figure 11).
Figure 11. Adding Diesel Fuel
MAYCO