Multiquip ST-45HRM CE manual ST-45HRMCE CONCRETE PUMP—TROUBLESHOOTINGHYDRAULIC, Symptom, Solution

Models: ST-45HRM CE

1 140
Download 140 pages 34.52 Kb
Page 68
Image 68
ST-45HRM CE CONCRETE PUMP—TROUBLESHOOTING (HYDRAULIC

ST-45HRM CE CONCRETE PUMP—TROUBLESHOOTING (HYDRAULIC

Practically all breakdowns can be prevented by proper handling and maintenance inspections, but in the event of a breakdown, please take a remedial action following the diagnosis based on the Hydraulic System Troubleshooting (Table 15) information shown below and on the proceeding page. If the problem cannot be remedied, please leave the unit just as it is and consult our company's business office or service plant.

TABLE 15. HYDRAULIC SYSTEM TROUBLESHOOTING

SYMPTOM

POSSIBLE PROBLEM

SOLUTION

 

 

 

 

 

Check TB1 terminal #17. If this terminal is energized when the

 

Delta "Q" compensator not de-energized

pump is turned on, the pump will not cycle because the

 

when pump is energized?

compensator is dumping controll pressure to the accumulator tank.

 

 

Check K-3 relay and replace if necessary.

 

 

 

 

Volume control not turned open?

Turm volume control valve counter-clockwise to open.

No hydraulic oil flow from axial piston

 

 

 

 

pump.

Hydraulic oil level low?

Fill resevouir to proper level.

 

 

 

 

 

Restricted suction screen?

Clean suction screen.

 

 

 

 

Main pressure relief valve open

Remove cartridge. Clean and reset. Replace cartridge if

 

ncessisary.

 

 

 

 

 

 

 

This emergency cycle switch, located in the control box, can be

 

Proximity switch is not sending a signal?

used to determine which switch is faulty. Determine malfunctioning

 

 

proximity switch and replace.

 

 

 

 

 

Turn on pump switch. Check TB1 terminal #35 and #36 to

 

Pilot cycle valve malfunction?

determine if current is flowing to valve. Check detents in valve for

Drive cylinders will not cycle

 

proper operation.

 

 

 

 

K-4 relay faulty?

Check the proximity switch enclosure.

 

 

 

 

Main cycle valve(manifold) faulty?

Check spool or centering springs. Replace or repair as necessary.

 

 

 

Accumulator pressure drops to zero

Low nitrogen charge in accumulator

Re-charge accumulator bladder with nitrogen to 7.58 mPa (1,100

on every cycle

bladder?

PSI.)

 

 

 

Accumulator pressure is below 12.1

Unloading valve setting too low?

Adjust unloading valve until 12.1 mPa (1,750 PSI) is reached.

mPa (1750 PSI.)

 

 

 

 

 

Accumulator pressure is not

Cartridge at port 4-D on manifold block

Check solinoid and cartridge. Replace if necessary

discharging when switch is turned off

is not working?

 

 

 

 

PAGE 68 — MAYCO ST-45HRM CE PUMP — OPERATION & PARTS MANUAL — REV. #0 (02/23/04)

Page 68
Image 68
Multiquip ST-45HRM CE manual ST-45HRMCE CONCRETE PUMP—TROUBLESHOOTINGHYDRAULIC, Hydraulic System Troubleshooting, Symptom