Multiquip ST-45HRM CE manual APPENDIX — ST-45HRMCE SHOTCRETE SYSTEM, Part No, Part Name

Models: ST-45HRM CE

1 140
Download 140 pages 34.52 Kb
Page 71
Image 71
PART NO.

APPENDIX — ST-45HRM CE SHOTCRETE SYSTEM

RECOMMENDED SHOTCRETE SYSTEM

 

NO.

PART NO.

PART NAME

QTY. REMARKS

1

EM28904

COUPLING, 3” H-D “CF”

 

2

EM23946

ELBOW, 3"x90°

 

3

EM28903

COUPLING, 2.5” H-D w/GASKET & PIN

 

4

EM28005DD

REDUCER, 3”x2.5”x36” H-D ENDS

 

5EM28061 PIPE, 2.5”x120w x 10’ H-D

6EM24849 HOSE, 2.5”x2”x36” H-D

7

EM28001DD REDUCER, 2.5”x2”x36” H-D

8EM23815D REDUCER, 2.5”x2” w/AIR VIBRATOR

9EM28902 COUPLING, 2” H-D w/GASKET & PIN

10EM23101 AIR VIBRATOR ASSY.

11

TBD

2”x2” ELBOW

12EM24841 HOSE, 2”x25’ H-D w/ENDS

13EM23808D NOZZLE ASSEMBLY, 2” H-D

14

EM23806

NOZZLE TIP, RUBBER 1-3/8”

15

EM23807

NOZZLE TIP, RUBBER 1.25”

General recommendations

If the site will permit, use steel pipe from the pump to the pool perimeter. It will reduce line pressures which is highly recommended.

The vibrator on the reducer by the pool improves pumpability.

Turn both air vibrators off whenever the pump is stopped to prevent separation of mix.

The air vibrators are low consumption (4.2 scfm).

Leave the air on at the nozzle when the pump is stopped to prevent clogging of air the hoses in the air insert.

Use item #11 (steel elbow) at the edge of the pool to prevent collapse of the rubber hose, which can cause blockage.

MAYCO ST-45HRM CE PUMP — OPERATION & PARTS MANUAL — REV. #0 (02/23/04) — PAGE 71