STARTING
CAUTION :
DO NOT attempt to operate this concrete pump until the Safety, General Information and Inspection sections have been read and understood.
EMERGENCY STOP SWITCH
1.There are 2 emergency stop switches (Figure 19). One is located on the the control box, the other is located on the other side of the pump near the heat exchanger. Both are provided for operator safety. In the event of an emergency, press either stop switch to stop the engine.
IGNITION SWITCH
3.To start the engine, insert the key (Figure 20) into the ignition switch and turn the key to the ON position.
Figure 20. Ignition Switch
4. Observe that the Air Filter and Oil Pressure status indicator lights are “ON” (Figure 21).The Battery status indicator light should be “OFF.”
Figure 19. Emergency Stop Switch
2.Turn both Emergency Stop switches
Figure 21. Status Indicator Lights
NOTE
NOTE
If either one of the Emergency Stop switches is in the “CLOSED” position (stop), the engine will not start.To start the engine, make sure that both Emergency Stop switches are in the “OPEN” position (fully extended).
Place all switches on the Hydraulic Control Box in the ”OFF” (up position).
A.Turn the key to the “START“ position and listen for the engine to start.
B.In warm weather let engine
C.The Air Filter, Oil Pressure and Battery indicator lights (Figure 21) should all be “OFF”.
If any of the status indicator lights
NOTE referenced in the ignition section (step 4) are “ON”, turn off the engine. DO NOT continue to run the engine.