Trap Setting
The Trap Setting enables the device to monitor events through the Web Management Utility, and to set the Trap IP Address where the trap event information is to be sent.
| Figure 26. Trap Setting |
System Events : | Monitoring the system’s trap. |
Device Bootup : | A trap is hit when booting up the system. |
Illegal Login : | A trap is hit when a user tries to log in using an incorrect |
| password, and it will record the IP address where the |
| incorrect login occured. |
Twisted Pair Port Events: | Monitoring the copper port status. |
Abnormal* Receive Error: | A trap where there was a receive data error in the copper |
| port. |
Abnormal* Transmit Error: | A trap where there was a transmit data error in the copper |
| port. |
* Abnormal is a 50 error packet count within 10 seconds.
YML711 Rev1 | NetComm 16 or 24 port Gigabit Switch |
www.netcomm.com.au | 31 |