NTI SERIMUX SERIES CONSOLE SWITCH

From the Port settings menu, the configuration of each port can be viewed and changed.

Setting

Description

 

Value

Port name

Change the port name

 

Max. 15 characters

Port type

Host or User

 

H

or U

In-band disconnect

Select characters to use for in-

 

1 + code for 1-character sequence (see table below)

sequence

band disconnect sequence

 

3 + desired characters for 3-character sequence

 

 

 

0- for no disconnect sequence

 

 

 

T-

display Control code list

Connection

Time left before connection will be

 

0-90 minutes. If 0 is selected, the connection will

Timeout

broken due to receiver inactivity

 

never timeout.

Serial settings

Display serial settings menu

 

N/a

Modem settings

Display modem settings menu

 

N/a

View port data

View the last 1016 characters

 

N/a

 

buffer

received and transmitted to/from

 

 

 

 

 

the port

 

 

 

 

VT100 displaying

Modify the displaying extra delay

 

0 = None,1 = normal, 2 = double, or 3 = triple

 

delay

 

 

"None" value can be used if the display is faster (i.e. with a

 

 

 

 

 

 

 

 

terminal emulator, like HyperTerminal, running on a PC); the

 

 

 

 

other values are useful if real terminals or slower serial

 

 

 

 

devices are used as user/administrator consoles.

 

Reset Port settings

Restores factory default port

 

A confirmation "Y" will be required

 

to default

settings

 

 

 

 

When [3] is pressed to change the in-band disconnect sequence, the choices provided are 0, 1, 3, or T. Pressing a [T] will bring up a Control code list containing key sequences used for 1-character sequences, and the ASCII codes associated with each. (See Fig. 7) To set a 1-character sequence, press [1], then the code from the table associated with the desired sequence.

Note: If the 3-character disconnect sequence is enabled, the string: [CR][LF]<3-char sequence>[CR][LF] has to be received to break the connection (7 characters). The [CR] and [LF] ASCII characters stand for 13 and 10 decimal codes (ASCII Carriage Return and Line Feed) respectively.

FYI: If the 1-character sequence is selected, the connected device will not receive the disconnect character. If the 3- character sequence is selected, it will be sent to the connected device, prior to breaking the connection.

Figure 7- Control Codes for in-band disconnect sequence

-

When selecting each new port setting values, press [Esc] or [Spacebar] to cancel, or press [Enter] to save.

-Press [>] (greater than symbol) to display the current settings for the next port.

-Press [<] (less than symbol) to display the current settings for the previous port

-Press [Esc] or [Spacebar] to return to the "Administrator main menu"