Network Technologies CS-16/8 Advanced Settings, Change administrator password, Keypad

Models: CS-16/8

1 79
Download 79 pages 56.69 Kb
Page 28
Image 28

NTI RACK MOUNT CONSOLE TERMINAL WITH CONSOLE SWITCH

3.1.6 Advanced Settings

From the "Administrator main menu", press [7] to display the “Advanced settings” menu.

 

Figure 18- Administrator's Advanced settings menu

From the "Advanced settings" menu the administrator can perform the following functions:

 

 

 

Setting

Description

Value

Administrator

Define the password to be used by the

Max. 31 characters.

Password

administrator

This can only be changed if old password is known.

 

 

(If SERIMUX is re-initialized (pg 30), the default password

 

 

(“nti”) will be restored)

Administrator

the time interval of administrator

0-90 minutes 0 = Never

Timeout

inactivity, prior to logging out.

 

Unit name

Name assigned to the SERIMUX

Max. 40 characters

User to auto login

User assigned to automatically login at

Index number of any enabled user that has access to the port

 

power up without a password.

being used for the user port

 

 

 

Connect two host

Connect two host ports together

Enter host port index number, press [Enter], second host port

ports

 

index number, and press [Enter] again

Firmware

Display the firmware menu

See pg. 19

Auto Refresh Period

Refreshes the admin screen after xx

0-90

 

minutes

 

Local KeyPad PIN

Defines the PIN number for Local

4 digit value 0000-9999 (default value is 9999)

 

keypad

 

FYI: If at power up the auto-login user does not have access to port being used, a login by a valid user with access rights will be required.

3.1.6.1 Change administrator password

For security purposes the administrator should change the factory default administrator password to a unique password. This will prevent unauthorized access to switch functions and CPUs. The password is needed to log in from any device, connected to any SERIMUX port in buffer mode.

To change the administrator password, from the Administrator main menu;

-press [7] to choose Advanced settings and press [Enter]. The Advanced settings menu will appear (Figure 18)

-press [1] and a prompt for the old password will appear

-enter the old password (factory default password is "nti") and press [Enter]

-enter a new password (maximum 31 ASCII characters), using the [Backspace] key to erase any characters entered in error, and press [Enter]

-re-enter the password to confirm it, and press [Enter]

-a message "OK" will appear, press any key to return to the Advanced settings menu

Note: The password entered will be case sensitive so be sure to note what characters are used and what case they are in if any are alphabetical. The password characters are displayed as ‘*’ (asterisk) characters while entering them.

Note: If the administrator password is not known, the administrator must re-initialize the SERIMUX following the "Reset SERIMUX Console Switch to default settings" instructions on page 30.

23

Page 28
Image 28