NTI RACK MOUNT CONSOLE TERMINAL WITH CONSOLE SWITCH
Disconnect 2 ports
Action (from Keypad) | Reaction of SERIMUX | |
1. | Press DISCON | - The LED “Discon” will illuminate. |
|
| - The port 0 LED will be illuminated, the other port LEDs will be OFF. |
2. | Press PORT | - |
3. | Enter the port number | - The corresponding port LED will illuminate, the other port LEDs will be OFF. |
4. | Press ENTER | - If command is successful the “Admin”,”Port”,”Discon”.,”User” LEDs will illuminate |
|
| together. They will turn OFF after 30 seconds or when any other key is pressed. |
Reaction of SERIMUX
- The LED “Discon” will illuminate.
-The port 0 LED will be illuminated, the other port LEDs will be OFF.
- The LED “Discon” will illuminate.
-The port 0 LED will be illuminated, the other port LEDs will be OFF.
-
-
- The corresponding port LED will illuminate. The other port LEDs will be OFF.
- If command is successful the “Admin”,”Port”,”Discon”.,”User” LEDs will illuminate together. They will turn OFF after 30 seconds or when any other key is pressed.
The modem will be initialized and connected if a modem is connected to the specified port and powered ON. The administrator can verify this by viewing the Port list (see page 13).
To detach a modem
Action (from Keypad) | Reaction of SERIMUX | |
1. | Press DISCON | - The LED “Discon” will illuminate. |
|
| - The port 0 LED will be illuminated, the other port LEDs will be OFF. |
2. | Press DISCON again | - The LED “Discon” will illuminate. |
|
| - The port 0 LED will be illuminated, the other port LEDs will be OFF. |
3. | Press 0 | - |
4. | Press PORT | - |
5. | Enter the port number | - The corresponding port LED will illuminate. The other port LEDs will be OFF. |
6. | Press ENTER | - If command is successful the “Admin”,”Port”,”Discon”.,”User” LEDs will illuminate |
|
| together. They will turn OFF after 30 seconds or when any other key is pressed. |
Reset SERIMUX Console Switch to default settings
SERIMUX can be reset to default settings using the Keypad. This procedure is only necessary if the administrator is unable to access the administrator main menu. This should only occur if an administrator password has been set and the password is not known.
The
1.Press and hold both local keypad “ADMIN” and “ESC” buttons.
2.Turn ON the
3.Wait 3 seconds.
4.Release the buttons.
Caution: During the reset, the customer modified parameter values will be replaced with the factory default values (for default values, see page 73, Appendix A); user names and passwords will return to default values (page 11).