Network Technologies CS-16/8 Appendix a Serimux Port Characteristics, Users, Administrator

Models: CS-16/8

1 79
Download 79 pages 56.69 Kb
Page 78
Image 78

NTI RACK MOUNT CONSOLE TERMINAL WITH CONSOLE SWITCH

Appendix A - SERIMUX Port Characteristics

Every port is defined through the following parameters:

 

Description

 

 

Acceptable Value

 

 

Default Value

 

 

 

 

 

 

 

 

Number

0-8/16/24/32

 

Same (not changeable)

 

Name

 

Up to 15 characters

 

 

“Port00” to “Port32”

 

Type – port 0

 

User

 

 

User (not changeable)

 

Type – except port 0

 

User or Host

 

 

Host

 

Baud rate – port 0

300-115200

 

9600

 

 

Baud rate – except port 0

50-128000

 

9600

 

 

Data bits per character – port 0

7,8

 

8

 

 

Data bits per character – except port 0

5,6,7,8

 

8

 

 

Stop bits – port 0

1, 2

 

1

 

 

Stop bits – except port 0

1, 1-1/2, 2

 

1

 

 

Parity

No parity, even, odd

 

 

No parity

 

Handshake mode (flow control)

 

Xon / Xoff (or in-band, or software),

 

None

 

 

 

 

RTS/CTS (or out-band or hardware),

 

 

 

 

 

 

 

Both,

 

 

 

 

 

 

 

 

None

 

 

 

 

 

Xon character

 

any ASCII nonprintable character

(0-31 range)

 

Ctrl+Q (17)

 

Xoff character

any ASCII nonprintable character

(0-31 range)

 

Ctrl+S (19)

 

Inter-character delay – except port 0

 

1-60 milliseconds, none

 

 

None

 

(no delay allowed on port 0)

 

 

 

 

 

 

 

Line break receive allowance – except port 0

 

Yes or No

 

 

No

 

(no allowance for port 0)

 

 

 

 

 

 

 

Transmitted line break extra duration (added

 

No break transmitted, 1-999 milliseconds

 

No break transmitted

 

to 1 character transmission time) – except

 

 

 

 

 

 

 

port 0 (no extra duration for port 0)

 

 

 

 

 

 

 

In-band disconnect sequence

 

0 (disabled), 1, or 3 characters sequence

 

1-char sequence

 

 

 

 

 

 

 

1 character disconnect sequence

 

Any ASCII nonprintable character (0-31 range)

 

Ctrl+X (24)

 

3 character disconnect sequence

 

Any 3 ASCII characters

 

 

``` (3 back quotes)

 

Connection timeout

 

1-90 minutes, never

 

 

15 minutes

 

DTR output upon disconnect

 

Low, high, or pulsed for 0.5 seconds and then held

 

High

 

 

 

 

high

 

 

 

 

 

Modem Reset string

 

Up to 41 characters

 

 

ATZ

 

Modem Initialization string

 

Up to 41 characters

 

 

AT&F&C1&D2S0=0

 

Modem Disconnect string

 

Up to 41 characters

 

 

ATH

Appendix B - SERIMUX User and Administrator Characteristics

The users and the administrator are defined through the following parameters:

 

Description

 

 

Acceptable Value

 

 

Default Value

 

 

 

 

 

 

 

 

Users:

 

 

 

 

 

 

 

User number

 

1 to 32

 

Same (not changeable)

 

User name

 

Up to 15 characters – case sensitive

 

“User01” to “User32”

 

User password

 

Up to 31 characters – case sensitive

 

“” (empty string)

 

User enabled

 

Yes or No

 

Not enabled, except

 

 

 

 

 

 

 

User 1: enabled

 

Administrative privileges

 

Yes or No

 

No

 

Access to ports

 

Port 0 always; Ports 1-31

 

Port 0, except

 

 

 

 

 

 

 

User 1: all ports

 

User menu timeout

 

1-90 minutes, never

 

15 minutes

 

Administrator:

 

 

 

 

 

 

 

Administrator name

“root” – case sensitive

Same (not changeable)

 

Administrator password

Up to 31 characters – case sensitive

 

“nti”

 

Administrator menu timeout

1-90 minutes, never

 

15 minutes

 

User to auto login

 

User 1-32, None

 

User 1

73

Page 78
Image 78
Network Technologies CS-16/8 Appendix a Serimux Port Characteristics, Description Acceptable Value Default Value, Users