NTI KEEMUX Series PS/2 KVM Switch

Configuration

All 4, 8, and 16-port units are configured using the 8-position dip-switch (located on the front of each unit) according to tables 1 and 2 below.

Front Panel Configuration Switches

Table 1 * (default settings)

Switch

SW1

SW5

SW6

STAND-ALONE SWITCH

OFF*

OFF*

OFF*

SLAVE

ON

OFF

OFF

MASTER W/4-PORT SLAVES

OFF

OFF

ON

MASTER W/8-PORT SLAVES

OFF

ON

OFF

MASTER W/16-PORT SLAVES

OFF

ON

ON

Table 2 * (default settings)

Master & Slave SW2-4 Settings

SW2

SW3

SW4

Master with-

Slave Setting

OFF*

OFF*

OFF*

No Slave Attached

N/A

OFF

OFF

OFF

1

Slave attached

Slave Unit #1

OFF

OFF

ON

2

Slaves attached

Slave Unit #2

OFF

ON

OFF

3

Slaves attached

Slave Unit #3

OFF

ON

ON

4

Slaves attached

Slave Unit #4

ON

OFF

OFF

5

Slaves attached

Slave Unit #5

ON

OFF

ON

6

Slaves attached

Slave Unit #6

ON

ON

OFF

7

Slaves attached

Slave Unit #7

ON

ON

ON

8

Slaves attached

Slave Unit #8

About Table 2:

These switch settings are used by the slave(s) to establish its identity (i.e. location in the group) to the master.

On a master, the same switches are used to configure the master for how many slaves are attached to it.

Cascaded Installation

1.Attach all slaves consecutively to the master switch.

a.Perform steps 1 and 2 under INSTALLATION on page 4 for each slave unit.

b.Configure each switch as per the tables above under CONFIGURATION before proceeding.

c.With a VEXT-xx-MM cable, connect slave #1 monitor port to master’s VIDEO 1 port.

d.With a VVKINT-xx-MM or (2) VKEXT-xx-MMs, connect slave #1’s PS/2 DEVICES ports to the master’s CPU1 KEYBOARD and MOUSE ports.

e.Repeat steps c and d for each additional slave unit, keeping in mind that each slave will connect to the next available master’s port (i.e. slave #2 to master’s VIDEO 2 and CPU 2 KEYBOARD and MOUSE, etc.). See Fig. 5 below.

If additional 4-PORT slaves are connected to VIDEO, PS/2 MOU CPU, & PS/2 KBD CPU ports 3 & 4, they will function and be controlled as CPU ports 9-12 and 13-16 respectively.

- OR-

If individual CPUs are connected

to ports 3 & 4, they will function and be controlled as CPU ports 9 & 10 respectively.

- +

MASTER UNIT (KEEMUX-P4)

CONNECT SLAVES FOR CASCADED

CPU CONNECTIONS

 

 

CPU 5-8

CPU 1-4

 

NTI

 

I

I

I

I

N

 

R

V

V

V

V

M

 

 

 

 

 

 

 

O

 

 

 

D

D

D

D

I

 

1275 Danner Dr

 

E

E

E

E

 

Aurora, OH 44202

T

 

O

 

O

O

O

 

www.nti1.com

 

 

 

2

 

R

 

Tel:330-562-7070

 

 

 

 

 

 

 

-562-1999

 

C

C

C

 

C

Mouse

 

 

Keyboard

 

P

 

P

 

 

 

 

 

 

 

Daisy

 

U

 

U

 

U

 

 

 

 

 

Out

 

4

3

2

 

1

 

 

 

 

 

 

CPU 4

CPU

2

CPU 1

PS/2 DEVICES

 

 

CPU 7

CPU 5

 

 

 

 

 

CPU 3

CPU 1

 

 

 

 

 

 

CPU 8

CPU 6

 

 

 

 

VVKINT-xx-MM

CPU 4

CPU 2

 

 

 

 

 

 

 

 

 

 

 

 

R

 

 

 

 

 

 

 

R

 

 

 

 

 

 

M

 

 

 

 

 

 

M

 

 

 

 

V

V

V

V

 

 

 

V

V

V

V

 

 

 

 

I

I

I

I

O

 

 

 

I

I

I

I

 

1275 Danner Dr

 

 

D

D

D

D

 

1275

Dr

 

D

D

D

D

I

 

 

E

E

E

E

T

Aurora,

44202

 

E

E

E

E

T

Aurora, OH 44202

 

 

O

O

O

O

www.

.com

 

O

O

O

O

O

www.nti1.com

 

 

O

 

 

 

 

 

 

 

4

3

2

1

R

Tel:330-

-7070

 

4

3

2

1

R

Tel:330-562-7070

 

 

 

 

 

 

 

-

-1999

 

 

 

 

 

 

Fax:330-562-1999

 

 

C

C

C

 

C

 

 

 

 

C

C

C

 

Mouse

 

 

 

 

Keyboard

 

 

 

P

Keyboard

 

 

5VDC

P

P

P

 

P

 

5VDC

 

P

P

P

 

 

 

Daisy

 

 

 

 

 

 

Daisy

Daisy

-

2A

U

U

U

 

U

Out

-

2A

 

 

U

U

U

Out

In

+

4

3

2

 

1

 

+

 

 

3

2

1

 

 

 

 

CPU 4

CPU 3

CPU 2

CPU 1

PS/2 DEVICES

 

 

 

CPU 4

CPU 3

CPU

 

DEVICES

 

SLAVE UNIT #2 (KEEMUX-P4)

SLAVE UNIT #1 (KEEMUX-P4)

For connection of CPUs 5-8

For connection of CPUs 1-4

Figure 6- Cable connections for cascading

6

Page 10
Image 10
Network Technologies KEEMUX-Px operation manual Configuration, Cascaded Installation