Installation

Button Trim Ring

Faceplate (outer surface shown)

Button openings

FIG. 19 Inserting the Button Trim RIng

9.Firmly press down around the Button Trim Ring until all of the latches are securely inserted into their openings on the Faceplate, and the Button Trim Ring is securely fastened. Verify the Button Trim Ring is firmly inserted onto the Faceplate and that there are no gaps between this Trim Ring and the outer surface of the Faceplate.

10.Place the Faceplate back onto the main NXD-1000Vi unit. Make sure to align the Microphone, Light, and PIR Motion sensor locations on the main unit to their respective openings on the Faceplate assembly.

Pre-Wall Installation of the Conduit Box

Wall Mount panels (NXDs) are contained within an outer housing (back box). This back box is not removed when installing the NXD into a Conduit Box (CB-TP10). The back box is only removed to gain access for the replacement of the internal components.

INSTALLER: LEAVE A GAP BETWEEN THE STUD AND CONDUIT BOX

MOUNTING TABS TO ACCOMMODATE THE DRYWALL or SHEETROCK.

This gap allows the installation of the drywall or sheetrock after the CB-TP10 Conduit

Box has been installed.

The CB-TP10 is an optional metallic box that is secured onto a stud/beam in a pre-wallsetting (where no walls are present). Installation procedures and configurations can vary depending on the installation environment. This section describes the installation procedures for the most common installation scenario. The most important thing to remember when mounting this conduit box is that the NXD- 1000Vi Mounting Tabs must lie flush against the outside of the sheetrock (FIG. 20).

Refer to SP-2259-02for detailed installation dimensions.

It is recommended that you cut out the surface slightly smaller than what is outlined in the installation drawings so that you can make any necessary cutout adjustments.

The wiring knockouts on the left side will be used for the NXD-1000Vi Wall Mount panel connectors, so always secure the conduit box to the stud using the Stud Mounting Holes on the right side of the box.

1.Rest the right Stud Mounting tabs onto the stud (keeping the knockouts on the left). Be sure to leave enough of a gap between the stud and NXD Mounting tabs to accommodate the