3.Remove the Faceplate/bezel (A in FIG. 23) from the main NXD unit (B in FIG. 23) by gripping the faceplate and pulling with gentle outward force.

4.Thread the incoming power, RJ-45, Ethernet, USB, and any optional audio/video wiring (from their terminal locations) through the surface opening. Leave enough slack in the wiring to accommodate any re-positioning of the panel.

5.Connect all data and power wiring connectors to their corresponding locations along the left side of the (un-powered) NXD touch panel.

Verify that the terminal end of the power cable is not connected to a power source before plugging in the 2-pin power connector.

The USB connectors can be from a either a USB extension cable, or a wireless USB RF transmitter.

Install the 3 included drywall clip sets into these locations

A - Faceplate

/Trim Ring

3 notches are required to accommodate the three expansion clips (included)

Expansion

Clips (3)

Mounting Tab

B - Main NXD unit consists of the touch panel and back box

FIG. 23 Wall Mount panel (NXD) installation configuration for drywall surfaces

6.Test the incoming wiring by attaching the panel connections to their terminal locations and applying power. Verify the panel is receiving power and functioning properly to prevent repetition of the installation.

7.Disconnect the terminal end of the power cable from the connected power supply.

Don’t disconnect the connectors from the touch panel. The unit must be installed with the attached connectors before being inserted into the drywall.

8.Install the three sets of drywall screws and expansion clips into the three oval notch locations along both sides of the main unit (B in FIG. 23).

9.Carefully insert the main unit (with expansion clips) into the cutout until the Mounting Tabs on the NXD unit lie flush against the wall.

32