Upgrading Modero Firmware

8.Click the New button to open the New TCP/IP Settings dialog where you can enter both a previously obtained DHCP or Static IP Address and an associated description for the connection into their respective fields.

9.Place a checkmark within the Automatically Ping the Master Controller to ensure availability radio box to make sure the Master is initially responding online before establishing full communication.

10.Click OK to close the current New TCP/IP Settings dialog and return to the previous TCP/IP Settings dialog where you must locate your new entry within the List of Addresses section.

11.Click the Select button to make that the currently used IP Address communication parameter.

12.Click OK to return to the Communications Settings dialog and place a checkmark within the Authentication Required radio box if your Master has been previously secured with a username/ password.

13.Click on the Authentication Required radio box (if the Master is secured) and then press the User Name and Password button to open the Master Controller User Name and Password dialog.

14.Within this dialog, you must enter a previously configured username and password (with sufficient rights) before being able to successfully connect to the Master.

15.Click OK to save your newly entered information and return to the previous Communication Settings dialog where you must click OK again to begin the communication process to your Master.

If you are currently connected to the assigned Master, a popup asks whether you would want to temporarily stop communication to the Master and apply the new settings.

16.Click Yes to interrupt the current communication from the Master and apply the new settings.

17.Click Reboot (from the Tools > Reboot the Master Controller dialog) and wait for the System Master to reboot. The STATUS and OUTPUT LEDs should begin to alternately blink during the incorporation. Wait until the STATUS LED is the only LED to blink.

18.Press Done once until the Master Reboot Status field reads *Reboot of System Complete*.

19.Click the OnLine Tree tab in the Workspace window to view the devices on the System. The default System value is one (1).

20.Right-click the associated System number and select Refresh System. This establishes a new connection to the specified System and populates the list with devices on that system. The communication method is then highlighted in green on the bottom of the NetLinx Studio window.

Step 2: Prepare the panel for communication via an IP

1.Press the blue Type field (from the Master Connection section) until the choice cycles to the word Ethernet.

2.Press the blue Mode field until the choice cycles to the word URL.

By selecting URL, the System Number field becomes read-only (grey) because the panel pulls this value directly from the communicating target Master (virtual or not). A Virtual Master system value can be set within the active AMX software applications such as: NetLinx Studio, TPD4, or IREdit.

3.Press the red Master IP/URL field to open a Keyboard and enter the NetLinx Master’s IP Address

(obtained from the Diagnostics - Networking Address dialog of the NetLinx Studio application).

4.Click Done to accept the new value and return to the System Configuration page.

5.Do not alter the Master Port Number value (this is the default value used by NetLinx).

72

10" Modero Widescreen Touch Panels

Page 82
Image 82
AMX NXD-1000Vi manual Prepare the panel for communication via an IP

NXD-1000Vi specifications

The AMX NXD-1000Vi is a sophisticated touchpanel designed for a multitude of installation environments, ranging from corporate boardrooms to educational institutions and high-end residential settings. This 10-inch color touchpanel exemplifies advanced technology combined with user-friendly features, making it a popular choice among integrators and end-users alike.

One of the standout features of the NXD-1000Vi is its high-resolution display, which measures 10.1 inches diagonally, providing a crisp and clear visual experience. The capacitive touchscreen allows for seamless navigation, supporting multi-touch gestures similar to those found on modern smartphones and tablets. This intuitive interface enables users to control AV systems, lighting, HVAC, and more with minimal learning curve.

The NXD-1000Vi incorporates advanced technologies such as Wi-Fi connectivity, which enhances flexibility in system design. This wireless capability allows for easy placement of the touchpanel without the constraints of Ethernet cabling, making it suitable for both new installations and upgrades. Additionally, it supports PoE (Power over Ethernet), providing power and data over a single cable, simplifying installation efforts by reducing the number of cables needed.

In terms of processing power, the NXD-1000Vi features rapid response times, ensuring that commands are executed swiftly. Coupled with its user-friendly graphical interface, this touchpanel allows for customization that can adapt to diverse user needs and preferences. It can be programmed to manage various devices and systems, making it a versatile solution for control in various environments.

The touchpanel also supports integrated video capabilities, allowing for the display of video feeds, making it ideal for monitoring and presentation purposes. Furthermore, it includes built-in speakers for audio feedback, enhancing the interactive experience for users.

Durability is a key characteristic of this device, as it is designed to withstand daily use in busy environments. Its sleek design not only looks professional but also ensures that it is easy to clean and maintain. With its robust set of features and adaptability, the AMX NXD-1000Vi stands out as an excellent choice for those looking to enhance their control system with an intuitive and reliable interface.