Modero NXD-1000Vi
AMX Limited Warranty and Disclaimer
FCC Information
Page
Table of Contents
Configuring Communication
Information
EAP Security & Server Certificates 129
Appendix a 199
Table of Contents Modero Widescreen Touch Panels
NXD-1000Vi 10 Widescreen Video Touch Panel Kits
Introduction
FG2259-04
Button Trim Ring is factory installed only on the FG2259-04
Specifications for 10 Widescreen Video Touch Panels
NXD-1000Vi Specifications
Side Panel Components
Front Panel Components
Operating / Storage
Included Accessories
Side Panel Components Cont
Button Assignments
NXA-AVB/ETHERNET CAT5
NXD-1000Vi Panels Connector Layout
NXA-AVB/ETHERNET Breakout Box front and rear views
NXA-AVB/ETHERNET Breakout Box
Installing the NXA-AVB/ETHERNET
Product Specifications
NXA-AVB/ETHERNET Specifications FG2254-10
NXA-AVB/ETHERNET
Wiring the NXA-AVB/ETHERNET connectors and cables
Audio In Left Channel
Wiring the NXA-AVB/ETHERNET for Balanced Audio
Wiring the NXA-AVB/ETHERNET for Unbalanced Audio
Balanced OUT
NXA-WC80211B/CF 802.11b Wireless Card FG2255-03
NXD-1000Vi Touch Panel Accessories
802.11b Wireless Interface Card Specifications
NXA-WC80211GCF 802.11g Wireless Card FG2255-07
Bus Interface
NXA-WC80211GCF Specifications
Media Access Control
Antenna Type
Receiver Sensitivity
Network Architecture
Information
Radio Technology
Touch Panel
Wireless LAN Security
Compatibility
Page
FG2116-77
Optional Compact Flash Upgrades
NXA-CFSP Compact Flash FG2116-7x
FG2116-76
Page
Remove the existing NXD Outer Housing
Installation and Upgrade of the Internal NXD Components
Location of the wireless CF card connector on main board
Install the new Compact Flash Memory card
Close and Resecure the NXD Panel Enclosure
Removing/installing a Compact Flash Memory card
Page
Installing the Internal Components
Installation
Installing the No-Button Trim Ring
Removing the default Button Trim Ring
Removing the No-Button Trim Ring
Installing the Button Trim Ring
Installer Leave a GAP Between the Stud and Conduit BOX
Pre-Wall Installation of the Conduit Box
Installing the NXD panel within a Conduit Box
Installation of an NXD Touch Panel
Touch panel and back box housing
NXD-1000Vi Wall Mount panel dimensions using expansion clips
Installing the NXD into drywall using Expansion Clips
Installation
Installing the NXD into a Flat Surface using #4 screws
Installation
Attachment is done along the edges of the cutout
Installation
Preparing captive wires
Wiring Guidelines for the NXD-1000Vi Panels
Wiring a power connection
Audio/Video RJ-45 Pinout Information
Audio/Video Port Connections and Wiring
Ethernet/RJ-45 Port Connections and Wiring
Pin Wire Color Function Polarity
Ethernet RJ-45 Pinouts and Signals
USB Port Connecting and Using Input Devices
Pin Signals Connections Pairing Color
Installation Modero Widescreen Touch Panels
Calibrating the Modero Panel
Panel Calibration
Touch Panel Calibration Screens
Testing your Calibration
Modero Setup and System Settings
Configuring Communication
Accessing the Setup and Protected Setup Pages
Setting the Panel’s Device Number
Wireless Settings Page Wireless Access Overview
Hot Swapping
Configure the Panel’s Wireless IP Settings
Configuring a Wireless Network Access
Wireless communication using a Dhcp Address
Using the Site Survey tool
Wireless communication using a Static IP Address
Site Survey
Configure the Card’s Wireless Security Settings
Panel connection IP info Wireless Card security settings
Required Information
Automatically set Ssid
Select Wireless Settings
Manually set Ssid
Locate the Wireless Security section FIG
These WEP Key identifier values must match for both devices
WEP Key # Keyboard
Select System Settings
Choose a Master Connection Mode
System Settings page USB Connection
USB driver installation popup window
Configure a Virtual NetLinx Master using NetLinx Studio
Assigning Communication Settings for a Virtual Master
Connection Modes
Mode Description Procedures
Ethernet
Master Connection to a Virtual Master via Ethernet
Configuring Communication
Ethernet
G4 Web Control
Using G4 Web Control to Interact with a G4 Panel
Configuring Communication
Using your NetLinx Master to control the G4 panel
Web Control VNC installation and Password entry screens
Configuring Communication
Upgrading Modero Firmware
Configure the panel for a USB Connection Type
Upgrading the Modero Firmware via the USB port
Prepare NetLinx Studio for communication via the USB port
Default Modero panel value is
Confirm and Upgrade the firmware via the USB port
Using USB for a Virtual Master transfer
Prepare the Master for communication via an IP
Upgrading the Modero Firmware via Ethernet IP Address
Prepare the panel for communication via an IP
Latest NXD-1000Vi firmware kit file is now panel-specific
Verify and Upgrade the panel firmware via an IP
Selected Firmware file
Protected Setup
Setup Navigation Buttons
Firmware Pages and Descriptions
Setup Page Elements
Setup
Panel Brightness
Timeout
Information
Inactivity Page Flip
Project Information Page Elements
Project Information
Panel Information Page Elements
Panel Information
Panel Type
Setup Port
Setup Pages Version
Power Up Pages
Time Display fields
Time & Date Setup
Time & Date Setup
Time Date Refresh/Set
Set Date/Time
Volume
Volume Page Elements
Master Volume
Intercom
Default Panel Sounds
Digital Audio Level
Analog
Supported sampling rates for WAV
Video Adjustment
Supported WAV Sampling Rates
Video Setup Page Elements
SIP
Protected Setup Navigation Buttons
Device Number
Protected Setup
Protected Setup Page Elements
Reboot Panel
Protected Setup page-System Recovery confirmation dialog
System Recovery
System Settings Page Elements
System Settings
Full Duplex
IP Settings
Master Connection
Wireless Settings
Wireless Settings
Network Name Ssid WAP names
Access Point MAC
Wireless Security
Address
RF Link Info
Site Survey
Secondary Connection
Wireless Security
Wireless Security Support
802.11g Wi-Fi CF card
Wireless Settings page Open Clear Text Settings
Open Clear Text Settings
Open Clear Text Settings
Static WEP Settings
Save/Cancel
Generate Passphrase
Static WEP Settings
Default Key
WEP 64 / WEP
Authentication
WPA-PSK Settings
Current Key
Password/Pass Phrase
WPA-PSK Settings
EAP-LEAP Settings
EAP-LEAP Settings
Ssid Service Set Identifier
Identity
Password
EAP-LEAP sample Cisco System Security
EAP-FAST Settings
Provisioning
EAP-FAST Settings
Anonymous Identity
Automatic PAC
Been Disabled
EAP-PEAP Settings
PAC File Location
Peap Version
EAP-PEAP Settings
Inner Authentication Type
Certificate Authority
EAP-TTLS Settings
EAP-TTLS Settings
MSCHAPv2 default because its the most common
EAP-TLS Settings
EAP-TLS Settings
Client Certificate
Client certificate configuration
Client Certificate Configuration
Private Key password
Certificate Type Possible File Extensions
Configuration Field Name Certificate File Type Supported
Certificates and their Extensions
Certificate Types Supported by the Modero Firmware
Calibration page actually 3 separate screens
Calibration
G4 Web Control
G4 Web Control Settings
G4 Web Control
G4 Web Control Timeout
Sensor Setup Page Elements
Sensor Setup
Motion Sensor
Dim Mode Minimum
Light Sensor
Light Level field
Sense
Wake Panel On Motion
Other Settings menu
Other Settings
Image Caching Page Elements
Image Caching
Image Cache Status
Image Cache Settings
Enable
Clear Cache
Checking image cache status
Setting the image cache
Password Setup
Clearing the image cache
Change
SIP Settings
Password Setup Page Elements
Panel Password
SIP Settings
Panel Logs
Tools
Panel Statistics
Checking the Panel Connection Logs
Refreshing the Panel Connections Log
Clearing the Panel Connections Log
Panel Statistics
Connection Utility
Checking the Panel Statistics
Refreshing the Panel Statistics
Clearing the Panel Statistics
Connection Utility
Using the Connection Utility
Overview
EAP Security & Server Certificates
Page
Setup
Panel Intercom Configuration
Full Duplex Intercom
Setting Intercom Auto Answer
Setting the Intercom Session Timeout
Allowing a panel to be monitored
Advanced Setup
Naming a panel
Allowing a panel to monitor
Sample Intercom
Sample Intercom
Name Description Channel Address Level PortCode
136 Modero Widescreen Touch Panels
Answering an incoming call
More Time Popup
Setup
Advanced Setup
Creating Intercom Pages
Button Assignments
Commands
Commands
Programming
@PHE
@CPG
@DPG
@PDR
@PPG
@PHT
@PPA
@PPF
@PPT
@PPK
@PPM
@PPN
@PST
@PPX
@PSE
@PSP
Ppog
Ppof
Ppon
Index No Name Red Green Blue
Programming Numbers
RGB triplets and names for basic 88 colors
RGB Values for all 88 Basic Colors
146 Modero Widescreen Touch Panels
Font styles and ID numbers
Default Font Styles and ID Numbers
Font ID Font type Size
Border styles
Border styles and Programming numbers
Border Styles and Programming Numbers
TPD4 Border Styles by Name
Modero Widescreen Touch Panels 149
ANI
Button Commands
Button Commands
Sendcommand Panel,ANI-500,1,25,100
BAT
APF
BAU
BCF
BCB
BCT
Entry is required
BDO
BFB
BIM
BMC
BLN
BMF-vt addr range,button states range,data
BMF
Cont
BNC
BMI
BML
BMP
BOP
BNN
BNP
BNT
BOS
BOR
BPP
BSM
BRD
BSF
BSP
BVP
BSO
BVL
BVN
ENA
BWW
CPF
DPF
GDI
FON
GIV
GRU
GLH
GLL
GRD
GSN-vt addr range,bargraph slider name
GSN
JSB
ICO
JSI
SHO
JST
MBT
MDC
TEF
TEC
TXT
Text Effects
Text Effects Names
UNI
Custom Event Fields
Button Query Commands
Defineevent
?BCB-vt addr range,button states range
Button Query Commands
Send Command Panel,?BCB-529,1
?BCB
?BCT
?BCF
?BOP
?BMP
?BWW
?BRD
?ICO
?FON
?JSI
?JSB
?TEC
?JST
?TEF-vt addr range,button states range
Send Command Panel,?TEF-529,1
Send Command Panel,?TXT-529,1
?TEF
Panel Runtime Operations
Panel Runtime Operation Commands
Brit
@AKP
@AKR
Beep
@PKP
Setup
@EKP
Pkeyp
@SWK
@SOU
@SSL
@SST
Wake
Tpageon
Tpageoff
@VKB
KPS
Input Commands
Input Commands
CAL
TPS
MPS
VKS
Embedded Codes
Embedded codes
Decimal numbers Hexidecimal values Virtual keystroke
Panel Setup Commands
Panel Setup Commands
MUT
Cfsm
CEX
DLD
@RPP
PWD
VOL
Dynamic Image Commands
Dynamic Image Commands
RAF-resource name,data
Panel Intercom Commands
Panel Intercom Commands
SIP Commands
SIP Commands
PHN-ANSWER
PHN-PRIVACY
PHN-REDIAL
Transferred
?PHN-PRIVACY
PHN-DTMF
PHN-HANGUP
PHN-HOLD
SIP Setup Commands
’PHN-SETUP-USERNAME, username’
PHN-SETUP Username
Sendcommand Panel,’PHN-SETUP-USERNAME, 6003’
Programming 198 Modero Widescreen Touch Panels
Formatting Code Operations
Appendix a
Text Formatting Codes for Bargraphs/Joysticks
Bargraph Text Code Inputs
Character Masking Rule
Text Area Input Masking
Input mask character types
Character Types
Input mask literals
Input mask ranges
Input mask next field characters
Input mask operations
Output Examples
Input mask output examples
Common Name Input Mask
Sequence Panel Information
URL Resources
Special escape sequences
Escape Sequences
Appendix a 204 Modero Widescreen Touch Panels
Overview of Wireless Technology
Appendix B Wireless Technology
802.1x
Terminology
Tkip
WPA2
Method Credential Type Authentication Pros Cons
EAP Authentication
EAP characteristics
EAP Method Characteristics
EAP security method in process
EAP communication overview
Setup the Panel and PC for USB Communication
Configuring your G4 Touch Panel for USB Communication
AMX Certificate Upload Utility
Confirm the Installation of the USB Driver on the PC
How to Upload a Certificate File
214 Modero Widescreen Touch Panels
Page
Page
Troubleshooting Information
Troubleshooting
Dhcp Address
Symptom Solution My Modero panel isn’t appearing
My Workspace window
My Modero panel can’t obtain a
My on-screen mouse cursor
Symptom Solution
Connecting
Blinking and it says the USB is
Studio 2.x application
Symptom Solution My WEP doesn’t seem to be
Working
My connected Masters
Behaves strangely
Connected to my System Master
Only one shows up
After downloading a panel file or
Troubleshooting 222 Modero Widescreen Touch Panels
Troubleshooting Modero Widescreen Touch Panels 223
It’s Your World Take Control