NTI AUDIO/HD VIDEO MATRIX SWITCH

Telnet Interface

The Telnet Interface enables the user to control the switch using telnet client through an Ethernet connection. The telnet server listens on port 2000. To access the telnet interface, using the current IP address type the following in a command shell:

telnet 192.168.1.1 2000

The VEEMUX-A will prompt the user for a password. The user must enter the password followed by <Enter>.

The factory default password is "admin".

With a proper password sent the VEEMUX-A will respond with:

Password Successful

Connection Established

The following commands are now available:

Command

Reply

Description

 

 

 

H(elp) or

Displays the list of commands

Help

h(elp)

 

 

CS nn,mm

*<CR>

Connect One Output nn To Input mm

 

 

 

CA nn

*<CR>

Connect All Outputs To Input nn

 

 

 

RO nn

*<CR>mm<CR>

Read Connection For Output.

Returns the number of the input mm connected to output nn

 

 

CC nn

*<CR>nn<CR>

Save Matrix Connections Into Memory Bank nn

nn should be between 00 and 99

 

 

RC nn

*<CR>nn<CR>

Restore Matrix Connections From Memory Bank nn

nn should be between 00 and 99

 

 

CB nn

*<CR>

Change baud rate of serial line, nn=12(00),24(00),48(00),96(00)

Factory default is 9600.

 

 

RV 00

*<CR>string<CR>

Read NTI Version String

 

 

 

RU

*<CR>nn,mm<CR>

Read Unit Size

Returns the number of inputs mm and the number of outputs mm

 

 

RS

*<CR>

Reset Unit

 

 

 

AS nn,mm

*<CR>

Connect audio input mm to output mm

 

 

 

AA nn

*<CR>

Connect audio input nn to all outputs

 

 

 

AO nn

*<CR>nn<CR>

Read audio connection for output nn

 

 

 

AM nn,mu

*<CR>

Set mute state for output nn

mu(te State) = (00=UNMUTE, 01=MUTE)

 

 

AV nn,vv

*<CR>

Set volume level for output nn

vv is a value between 00 to 99 (see chart page 12)

 

 

 

 

Read mute, volume for output nn

AR nn

*<CR>MU,VV<CR>

MU is 00 if the port is UNMUTED, MU is 01 if the port is MUTED.

 

 

VV is a value between 00 to 99 (see chart page 12)

 

 

Set value of Scan Mode dwell time (see page 9) for specific Output

Ss nn,dwt

*<CR>

(nn)

 

 

dwt = 000-255 (seconds) 000= disable Scan Mode

Gs nn

*<CR>

Read set Scan Mode dwell time value (dwt) for specific Output (nn)

dwt<CR>

in seconds (see also "Scan Mode" on page 9)

 

Sa nn,mm

*<CR>

Set scan list of individual output nn to all inputs mm

 

 

 

14