DUST AND DEBRIS COLLECTION SYSTEM

SUCTION INLET DISASSEMBLY/ASSEMBLY

Disassembly

1.Remove the side brooms (see the procedure in the relevant paragraph).

2.Lower the suction inlet (12), according to the procedure shown in the User Manual.

3.Engage the parking brake with the lever (66).

4.Turn the ignition key (76) to OFF position and remove it.

5.Disconnect the hydraulic system hoses (A) and (B) from the suction inlet (C) and plug them.

6.Disconnect the dust control system water hose (D).

7.Remove the nuts (E) and pins (F).

8.Move the suction inlet (C) forward, and loosen the suction hose clamp (G).

9.Disconnect the suction hose (H) from the suction inlet.

10.Remove the suction inlet (C).

Assembly

11.Assemble the components in the reverse order of disassembly.

If necessary, perform the suction inlet and skirt height and operation check (see the procedure in the relevant paragraph).

FB H

A

G

D

E

E

F

C

S301487

RS 501

33015500(3)2008-02

33