Nilfisk-Advance America RS 501 service manual Alternator Belt Replacement

Models: RS 501

1 146
Download 146 pages 24.25 Kb
Page 85
Image 85

SERVICE MANUAL

ENGLISH

LDW 1603/B2 ENGINE

ALTERNATOR BELT REPLACEMENT

1.Empty the hopper (3); if it contains a small quantity of waste, it is not necessary to dump it.

2.Drive the machine on a solid and level ground, then engage the parking brake with the lever (66).

3.Lift the hopper (3), according to the procedure shown in the User Manual.

4.Turn the ignition key (76) to OFF position and remove it.

5.Open the right lid (20) by releasing the fasteners (21) with the supplied key.

6.Remove the locking pins (28) from the housings (29) and place them into the holes (30).

7.Empty the dust control system water tanks (7 and 16) according to the procedure shown in the relevant paragraph.

8.Remove the screw (44) and open the right tank (43).

WARNING!

Open the tanks (7 and 16) only if they are empty: each tank contains 120 kg of water approximately.

9.Replace and adjust the alternator belt tension according to the procedure shown in the Diesel Engine Manual.

10.Perform steps 3, 4, 5, 6 and 8 in the reverse order.

11.If necessary, fi ll the dust control system water tanks according to the procedure shown in the User Manual.

RS 501

33015500(3)2008-02

83

Page 85
Image 85
Nilfisk-Advance America RS 501 service manual Alternator Belt Replacement