SERVICE MANUAL

ENGLISH

OTHER SYSTEMS

OTHER SYSTEMS

NUT AND SCREW TIGHTENING AND LEAKAGE CHECK

1.Empty the hopper (3); if it contains a small quantity of waste, it is not necessary to dump it.

2.Drive the machine on a solid and level ground, then engage the parking brake with the lever (66).

3.Open the right and left lids (20) and (18) by releasing the fasteners (21) and (19) with the supplied key.

4.Lift the hopper (3), according to the procedure shown in the User Manual.

5.Turn the ignition key (76) to OFF position and remove it.

6.Remove the locking pins (28) from the housings (29) and place them into the holes (30).

7.Empty the dust control system water tanks (7 and 16) according to the procedure shown in the relevant paragraph.

8.Remove the screw (44) and open the right tank (43).

WARNING!

Open the tanks (7 and 16) only if they are empty: each tank contains 120 kg of water approximately.

9.Remove the screw (42) and open the left tank (41).

10.Inspect the machine accessible parts and check for:

Tightening of mounting screws and nuts;

Correct position of the fasteners;

Visible faults in the components;

Leaks of fl uids (oil, etc.).

11.Perform steps 3, 4, 5, 6 and 8 in the reverse order.

12.If necessary, fi ll the dust control system water tanks according to the procedure shown in the User Manual.

RS 501

33015500(3)2008-02

95

Page 97
Image 97
Nilfisk-Advance America RS 501 service manual Other Systems, NUT and Screw Tightening and Leakage Check