OPERATING INSTRUCTIONS

DUST CONTROL

KNOB

DUST CONTROL

PANEL FILTER

Fig. 57

Fig. 58

DUST CONTROL KNOB

The dust control knob is used to hold the dust control filter cover down as shown in figure 57. The dust control filter is located under the front cover and will need to be removed periodically for cleaning or replacement. Removal of the filter panel requires no tools. The front cover must be opened to gain access to the filter compartment. The panel filter is held in place by a hinged frame and knob. To remove the panel filter, turn the knob counterclockwise and lift the hinged frame. The panel filter can now be lifted out and cleaned or replaced. To install the replacement panel filter, place a new filter in the machine, lower the frame and twist the knob clockwise to lock the filter in place.

FILL WITH

HYDRAULIC FLUID

CHECK FLUID LEVEL

Fig. 59

HYDRAULIC RESERVOIR LEVEL SIGHT GAUGE

The sight gauge is located on the right side of the machine under the front cover as shown in figure 59. The sight gauge is used to indicate the level of fluid in the reservoir. The fluid level must be visible in the sight gauge when the hopper is in the down position.

AMERICAN-LINCOLN

1-43

SMART

 

Page 43
Image 43
Nilfisk-ALTO 692003 manual Dust Control Knob, Hydraulic Reservoir Level Sight Gauge