When the STATUS Indicator is Lit/Blinks

When the STATUS indicator of the main unit operation panel is lit or blinks, notification is being given of the irregularities de- scribed.

STATUS indicator

POWER indicator

 

STATUS

POW

 

 

 

ER

 

 

 

POWER

 

 

MENU

 

SOURCE

 

 

 

 

 

QUICK

 

AUTO

 

MENU

 

AUDIO

 

 

 

VIDEO

 

 

 

STATUS Indicator POWER Indicator

Action to Take

The temperature has become abnormally high.

*The thermal protector is activated. If the room tem-

perature is high, move the projector to a cool lo-

cation. If the internal temperature of the projector

STATUSPOWERis high, check the ventilation holes of the cooling fan and clean them if they are obstructed.

*When the thermal protector is activated, the power is switched off and even if the power is soon

Blinks red

Lit red

switched back on, the power might not actually

(0.5 s lit / 0.5 s off)

 

 

be supplied to the projector. Should this happen,

 

 

 

 

wait one minute and then switch the power on

 

 

 

 

again.

 

 

 

 

If the power still does not come on, wait approxi-

 

 

 

 

mately 60 minutes until the internal temperature

 

 

 

 

of the projector drops, then switch on the power

 

 

 

 

again.

 

 

 

 

When the aforementioned procedure does not

 

 

 

 

solve the problem, please contact Olympus Digi-

 

 

 

 

tal Technical Support.

 

 

 

 

 

STATUS

POWER

The lamp will not light up.

 

 

Wait one minute or longer while the lamp lighting volt-

 

 

 

 

 

 

 

 

age irregularity detection protector is activated and

 

 

 

 

 

 

 

 

switch the power on again. If the problem still per-

Blinks red

 

 

sists, unplug the power cable and contact Olympus

 

 

Digital Technical Support.

(1 s lit / 1 s off)

 

 

 

 

 

When the lamp burns out during operation: Blinks amber for 90 seconds and then is lit amber

When the lamp does not light from the beginning: Lit amber

E-61