HOSE FITTING
The input port(s) on the instrument are designed to accept a hose with 4mm I.D. and 1mm wall. The hose is fitted by unscrewing the clamping nut, sliding the hose on to the stepped shaft and refitting the nut.
Note: Do not tighten fittings attached to the pressure ports to a torque greater than 2Nm otherwise the pressure seals may be damaged.
HAND PUMP OPERATION (if applicable)
Use the T piece to connect the hand pump to the instrument’s + port and to the equipment being tested. Exhaust the system by turning the release valve on the hand pump
Close the release valve and apply pump action to the hand pump piston to generate the required approximate pressure. Fine adjustment of the desired pressure can then be made by rotating the threaded piston. The release valve may be used to vent the system. Note: The hand pump is capable of generating 7bar max. It is, therefore, essential that extra care is taken not to
A pump must not be used on models
PLUS FUNCTIONS
Models
SMOOTHING MODE
Press = key and the instrument continuously averages the last four measurements to give a more stable reading on the display. Press = key again to return to normal measurement.
UNITS OF PRESSURE
Press key to select required units of pressure. Chosen units will be saved when the instrument is switched off.
Please refer to the table on the back page.
The
This function will not operate while in store mode. Note:
K = x 103 when using in H2O and Pa. M = x 106 when using in H2O and Pa.
MAX/MIN RECORDER
Press | key to start. The instrument will display alternating | |
| symbols and current reading. Press again to display the | |
maximum pressure reading and | symbol will be displayed. | |
Press again to display the minimum pressure reading and |
symbol will be displayed. Press again to return to the actual pressure display.
Press X key to display the average pressure since the MAX/MIN
mode was activated and symbol will appear on display.