Status Error Screens

STATUS/FX/PAGE1-------------------

STATUS/FX/PAGE2-------------------

choose category:

 

choose category:

MODES METER BATT

PG2

PG1 ERROR WARN PG3

Pressing the <PG2> soft key brings up more STATUS categories.

Pressing the <ERROR> soft key brings up the first ERROR screen.

Pressing the <DOWN> soft key brings up successive METER screens.

STATUS/FX/ERROR-----------

P00

STATUS/FX/ERROR----------

P00

STATUS/FX/ERROR----------

P00

low ac output

 

No

stacking

 

No

inverter

 

No

voltage

 

 

error detected

 

overtemp

 

 

DOWN

STATUS

PORT

DOWN

UP

TOP PORT

DOWN UP

TOP

PORT

STATUS/FX/ERROR----------

P00

STATUS/FX/ERROR----------

P00

STATUS/FX/ERROR----------

P00

low battery

No

phase loss

 

No

high battery

 

No

voltage

 

error

 

 

voltage

 

 

DOWN UP

TOP PORT

DOWN UP

TOP

PORT

DOWN UP

TOP

PORT

STATUS/FX/ERROR----------

P00

STATUS/FX/ERROR----------

P00

STATUS/FX/ERROR------------------

ac output

 

No

ac output

 

 

end of error menu

 

shorted

 

 

backfeed

 

 

 

 

DOWN UP

TOP

PORT

DOWN UP

TOP

PORT

UP

TOP STATUS

Push <TOP> to

Push <STATUS> to

return to the first

return to the “choose

ERROR screen.

category” STATUS /

 

FX/PAGE2 screen.

ERROR Screens

All screens read status as “No” under normal conditions. If the unit shuts off due to a specified error condition, that screen will change to “Yes”.

low ac output voltage: load too high; Inverter could not supply enough AC voltage to meet demand

stacking error detected: communication problem among stacked units

inverter overtemp: Inverter has reached its maximum allowed operating temperature

low battery voltage: battery voltage is below the LOW BATTERY CUT-OUT VOLTAGE set point (This error can be triggered by other events. It can trigger with low AC output or AC shorted.)

phase loss error: not active in the OBX-IC2024S-120/60 Inverter

high battery voltage: battery voltage rose above the safe high battery voltage level for 10 seconds

ac output shorted: Inverter reached its maximum current and shut down

ac output backfeed: usually indicates another AC power source was connected to the Inverter’s AC output

These are hard faults. The Inverter must be turned off and then on to reset. ERROR screens can only display errors; they do not offer any means to correct them. Generally the nature of the error suggests how to correct it.