Insert fasteners at all four corners of the Inverter for a secure installation.

12.0” (30.48 cm)

16.25” (41.27 cm)

8.25” (20.95 cm)

MOUNTING

The Inverter weighs 57.5 lbs (26.08 kg) and must be secured with appropriate fasteners to a sturdy mounting surface capable of supporting its weight. Depending on application, it may be easier for two people to install the unit due to the Inverter’s weight.

If internally mounted (protected from the environment), the Inverter can be mounted in any position or orientation. If externally mounted (exposed to the environment), the Inverter cannot be mounted upside-down, to ensure that water will not stand under the DC cover. (It can be mounted in any other position or orientation.) In all cases, the Inverter will perform better in locations offering plenty of air circulation.

When mounting the Inverter on a given surface, use appropriate fasteners to support its weight. OutBack cannot be responsible for damage to the Inverter if it is attached with inadequate fasteners.

Install and secure each Inverter before attaching any wiring.

If mounted on a tracked or other non-suspension-type profile, consideration should be made to use shock dampening technology betwen the platform and the Inverter chassis due to the potential vibration and other mechanical energy transfer.

6

Page 8
Image 8
Outback Power Systems OBX-IC2024S-120/60 owner manual Mounting