Setup menus

USER menu

<INTERFACE>

 

Item

 

Setting

 

 

 

 

 

 

 

 

 

 

 

Description

No.

Superimposed

No.

 

Superimposed

 

display

 

 

display

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

200

PARA RUN

0000

 

 

DIS

 

This selects whether two or more VTRs are to be operated in

 

 

0001

 

 

ENA

synchronization.

 

 

 

 

 

 

 

 

0: No operation in synchronization

 

 

 

 

 

 

 

 

1: Operation in synchronization

 

 

 

 

 

 

 

 

<Note>

 

 

 

 

 

 

 

 

When operating two or more VTRs in synchronization, set

 

 

 

 

 

 

 

 

item 200 of all the VTRs to 0001.

 

 

 

 

 

 

 

 

 

201

9P SEL

0000

 

 

OFF

This selects whether the 9P connector functions when the

 

 

0001

 

 

ON

REMOTE/LOCAL switch has been set to REMOTE.

 

 

 

 

 

 

 

 

0: Do not function

 

 

 

 

 

 

 

 

1: Function

 

 

 

 

 

 

 

 

 

202

ID SEL

0000

 

 

OTHER

 

This selects the ID information which is returned to the

 

 

0001

 

 

DVCPRO

controller.

 

 

 

 

 

 

 

 

0: 20

25H

 

 

 

 

 

 

 

 

1: DVCPRO’s, own ID is returned (F0 33H).

 

 

 

 

 

 

 

 

 

203

25P SEL

0000

 

 

OFF

 

This selects whether the PARALLEL (25P) connector

 

 

0001

 

 

ON

functions when the REMOTE/LOCAL switch has been set to

 

 

 

 

 

 

 

 

REMOTE.

 

 

 

 

 

 

 

 

0: Does not function

 

 

 

 

 

 

 

 

1: Functions

 

 

 

 

 

 

 

 

 

204

RS232C SEL

0000

 

 

OFF

 

These settings are for selecting whether the RS-232C

 

 

0001

 

 

ON

connector is to function when the REMOTE/LOCAL switch is

 

 

 

 

 

 

 

 

set to REMOTE.

 

 

 

 

 

 

 

 

0: Connector does not function.

 

 

 

 

 

 

 

 

1: Connector functions.

 

 

 

 

 

 

 

 

 

205

BAUD RATE

0000

 

300

 

 

These settings are for selecting the RS-232C communication

 

 

0001

 

600

 

 

speed (baud rate).

 

 

0002

 

1200

 

 

 

 

 

0003

 

2400

 

 

 

 

 

0004

 

4800

 

 

 

 

 

0005

 

9600

 

 

 

 

 

 

 

 

 

 

 

 

 

206

DATA

0000

 

7

 

These settings are for selecting the RS-232C data length.

 

LENGTH

0001

 

8

 

 

(Unit: bit)

 

 

 

 

 

 

 

 

 

207

STOP BIT

0000

 

 

1

 

 

These settings are for selecting the RS-232C stop bit length.

 

 

0001

 

2

 

(Unit: bit)

 

 

 

 

 

 

 

 

 

208

PARITY

0000

 

 

NON

 

These settings are for selecting the none, odd or even for the

 

 

0001

 

 

ODD

RS-232C parity bit.

 

 

0002

 

 

EVEN

0: Parity bit is not used.

 

 

 

 

 

 

 

 

1: An odd number of bits is used for the parity system.

 

 

 

 

 

 

 

 

2: An even number of bits is used for the parity system.

 

 

 

 

 

 

 

 

209

RETURN

0000

 

 

OFF

These settings are for selecting whether the ACK code is to be

 

ACK

0001

 

 

ON

returned when a command is received from RS-232C.

 

 

 

 

 

 

 

 

0: ACK code is not returned.

 

 

 

 

 

 

 

 

1: ACK code is returned.

 

 

 

 

 

 

 

 

210

25P STBY

0000

 

 

OFF/ON

 

This selects the method used to detect the STANDBY

 

CMD

0001

 

 

ON

COMMAND signal input at the PARALLEL (25P) connector.

 

 

 

 

 

 

 

 

0: Each time active signals are detected, the STANDBY ON or

 

 

 

 

 

 

 

 

STANDBY OFF mode is selected alternately.

 

 

 

 

 

 

 

 

1: When active signals are detected in the STANDBY OFF

 

 

 

 

 

 

 

 

mode, the unit is transferred to the STANDBY ON mode.

 

 

 

 

 

 

 

 

No effect is exerted on operation while the STANDBY ON

 

 

 

 

 

 

 

 

mode is established.

The underline on the setting item denotes the initial setting.