Table of AUTO OFF Error messages

Counter display

Monitor display

Description

VTR operation

(Restart condition)

 

 

 

 

 

 

 

CAP ROTATE TOO

CAP ROTA TOO

If the capstan motor speed is abnormally low, the

STOP

SLOW

SLOW

AUTO OFF lamp lights, and the message display

(POWER OFFON)

 

 

flashes.

 

CAP TENSION ERROR

CAP TENSION ERROR

If an abnormal tension at the supply side is detected

STOP

 

 

in the capstan mode, the AUTO OFF lamp lights, and

 

 

the message display flashes.

(POWER OFFON)

 

 

 

 

 

 

 

DEW

DEW

If condensation is detected, the AUTO OFF lamp

 

 

 

lights, the message display flashes, and the VTR is

 

 

 

transferred to the eject mode. After the tape is

 

 

 

ejected, the drum rotates in order to eliminate the

 

 

 

condensation.

EJECT

 

 

When the condensation has been eliminated, the

 

 

AUTO OFF lamp and message display go off, and

(Normal operation

 

 

the VTR can be used.

resumed after

 

 

<Notes>

condensation is

 

 

1) If condensation is detected in the eject mode, the

eliminated)

 

 

drum starts rotating as soon as it is detected.

 

 

 

2) If condensation is detected when the cassette

 

 

 

has been inserted, the drum rotation is stopped,

 

 

 

and after the tape is ejected, the drum starts

 

 

 

rotating.

 

 

 

 

 

DRUM ROTATE TOO

DRUM ROTA TOO

If the cylinder motor speed is abnormally high, the

STOP

FAST

FAST

AUTO OFF lamp lights, and the message display

(POWER OFFON)

 

 

flashes.

 

DRUM ROTATE TOO

DRUM ROTA TOO

If the cylinder motor speed is abnormally low, the

STOP

SLOW

SLOW

AUTO OFF lamp lights, and the message display

(POWER OFFON)

 

 

flashes.

 

E-FF

E-FF

If the tape start and tape end are detected simulta-

STOP

 

 

neously either during or after loading, the AUTO OFF

(POWER OFFON)

 

 

lamp lights, and the message display flashes.

 

FRONT LOAD ERROR

FRONT LOAD ERROR

The AUTO OFF lamp lights and the message display

 

 

 

flashes when the take-up reel has been rotating idly

STOP

 

 

for a fixed period of time while the start/end

 

 

processing operation during loading (half position) is

(POWER OFFON)

 

 

being performed or when it was impossible to eject

 

 

 

the tape.

 

 

 

 

 

FRONT LOAD MOTOR

FRONT LOAD MOTOR

If the cassette does not move up even when 6

 

 

 

seconds have elapsed since the VTR was transferred

 

 

 

to the eject mode, the AUTO OFF lamp lights, and

 

 

 

the message display flashes.

STOP

 

 

<Note>

 

 

(POWER OFFON)

 

 

If the cassette does not move down inside the

 

 

machine even when 6 seconds have elapsed since

 

 

 

the cassette was inserted, the VTR is transferred to

 

 

 

the eject mode.

 

 

 

 

 

LOADING MOTOR

LOADING MOTOR

When the unloading operation is not completed within

 

 

 

6 seconds, the AUTO OFF lamp lights, and the

 

 

 

message display flashes.

STOP

 

 

<Note>

 

 

(POWER OFFON)

 

 

When the loading operation is not completed within 6

 

 

seconds, the VTR is transferred to the eject (unload-

 

 

 

ing) mode.

 

 

 

 

 

– 90 –

Page 90
Image 90
Panasonic AJ-D850P Table of Auto OFF Error messages, Counter display Monitor display Description VTR operation, Eject