Error messages

Error messages

Display

• Description

• VTR operation and remedial action

 

 

 

 

 

FRONT LOAD

If the cassette fails to move up even after 6 seconds

MOTOR

have elapsed since the VTR transferred to the EJECT

 

mode, the AUTO OFF lamp lights, and the message

 

display blinks.

 

<Note>

 

If the cassette fails to move down even after 6 seconds

 

have elapsed since the cassette was inserted, the VTR

 

transfers to the EJECT mode.

 

VTR:

Stops.

 

• Set the POWER switch to OFF and then back to ON

 

again.

 

 

LOADING

If the unloading operation fails to be completed within 6

MOTOR

seconds, the AUTO OFF lamp lights, and the message

 

display blinks.

 

<Note>

 

If the loading operation fails to be completed within 6

 

seconds, the VTR transfers to the EJECT mode

 

(unloading mode).

 

VTR:

Stops.

 

• Set the POWER switch to OFF and then back to ON

 

again.

 

 

REEL DIR

If the take-up reel motor is running in the reverse

UNMATCH

direction, the AUTO OFF lamp lights, and the message

 

display blinks.

 

VTR:

Stops.

 

• Set the POWER switch to OFF and then back to ON

 

again.

 

 

REEL

If an abnormal tension at the supply side is detected in

TENSION

the reel mode, the AUTO OFF lamp lights, and the

ERROR

message display blinks.

 

VTR:

Stops.

 

• Set the POWER switch to OFF and then back to ON

 

again.

 

 

SERVO COMM

When the servo microcomputer does not follow the

ERROR

instructions of the system control microcomputer even

 

after 10 seconds have elapsed, the AUTO OFF lamp

 

lights, and the message display blinks.

 

VTR:

Stops.

 

• Set the POWER switch to OFF and then back to ON

 

again.

 

 

 

SERVO

When

there is no response from the servo

CONTROL

microcomputer for 1 or more seconds, the AUTO OFF

ERROR

lamp lights, and the message display blinks.

 

VTR:

Stops.

 

• Set the POWER switch to OFF and then back to ON

 

again.

 

 

SERVO

When only the servo microcomputer was reset in an

ERROR

instantaneous power failure, etc., the AUTO OFF lamp

 

lights, and the message display blinks.

 

VTR:

Stops.

 

• Set the POWER switch to OFF and then back to ON

 

again.

 

 

 

Display

• Description

 

• VTR operation and remedial action

 

 

 

 

 

 

 

 

 

 

 

S-FF/REW

When the tape start or end processing operation is not

 

TIMEOVER

completed, the AUTO OFF lamp lights, and

the

 

message display blinks.

 

 

VTR:

Stops.

 

 

• Set the POWER switch to OFF and then back to ON

 

again.

 

 

 

 

 

S REEL ROTA

If the supply reel motor rotates at an abnormally fast

 

TOO FAST

rate, the AUTO OFF lamp lights, and the message

 

display blinks.

 

 

VTR:

Stops.

 

 

• Set the POWER switch to OFF and then back to ON

 

again.

 

 

 

 

 

S REEL

If an abnormal torque applied to the supply reel motor

 

TORQUE ERR

is detected or if an abnormal current flowing to the

 

 

current-sensing resistor is detected, the AUTO OFF

 

lamp lights, and the message display blinks.

 

 

VTR:

Stops.

 

 

• Set the POWER switch to OFF and then back to ON

 

again.

 

 

 

 

 

T REEL ROTA

If the take-up reel motor rotates at an abnormally fast

 

TOO FAST

rate, the AUTO OFF lamp lights, and the message

 

display blinks.

 

 

VTR:

Stops.

 

 

• Set the POWER switch to OFF and then back to ON

 

again.

 

 

 

 

 

T REEL

If an abnormal torque applied to the take-up reel motor

 

TORQUE ERR

is detected, the AUTO OFF lamp lights, and

the

 

message display blinks.

 

 

VTR:

Stops.

 

 

• Set the POWER switch to OFF and then back to ON

 

again.

 

 

 

 

 

UNLOAD

If the tape has not been wound up during unloading,

 

ERROR

the AUTO OFF lamp lights, and the message display

 

 

blinks.

 

 

 

 

VTR:

Stops.

 

 

• Set the POWER switch to OFF and then back to ON

 

again.

 

 

 

 

 

WINDUP

If, after the total tape amount has been detected, the

 

ERROR

amount of tape wound up onto the take-up reel and the

 

 

amount of tape supplied by the supply reel differ to an

 

 

abnormal extent while the tape is traveling, the AUTO

 

 

OFF lamp lights, and the message display blinks.

 

 

VTR:

Stops.

 

 

• Set the POWER switch to OFF and then back to ON

 

again.

 

 

 

 

 

W-UP REEL

If, after the cassette has been inserted, the tape take-

 

NOT ROTA

up reel has not wound up the tape while the total tape

 

 

amount is not detected and while the tape is traveling,

 

 

the AUTO OFF lamp lights, and the message display

 

 

blinks.

 

 

 

 

VTR:

Stops.

 

 

• Set the POWER switch to OFF and then back to ON

 

again.

 

 

 

 

 

 

If the error message display persists even after the VTR has been shut down and started up again, consult your dealer.

121

Page 121
Image 121
Panasonic AJ-HD1700 manual 121