Setup menus

<INTERFACE>

No./Item

 

 

 

 

 

 

 

Description of setting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

200

For selecting whether to operate two or more

 

 

VTRs in synchronization.

 

 

 

 

PARA RUN

0000

 

 

 

 

DIS

: The

VTRs are not operated in

 

 

 

 

 

 

 

 

 

 

 

synchronization.

 

 

0001

 

 

ENA

:

The

VTRs

are operated in

 

 

 

 

 

 

 

 

 

 

 

synchronization.

 

 

<Note>

 

 

 

 

 

 

 

 

 

 

 

 

To operate the VTRs in synchronization, set all the

 

VTRs to 1 (ENA). (Refer to pages 14 and 19.)

 

 

 

 

 

 

 

 

202

For

setting what

 

ID information is to be

 

returned to the controller.

 

 

 

ID SEL

0000

 

OTHER

 

 

 

 

 

 

 

 

0001

 

 

DVCPRO

 

 

 

 

 

 

 

0002

 

 

ORIG

 

 

 

 

 

 

 

<Notes>

 

 

 

 

 

 

 

 

 

 

 

 

For 0 (OTHER), the ID information of VTRs other than

 

 

DVCPRO models is set.

 

 

 

 

 

Select 2 (ORIG) only when the VTR is connected to a

 

 

Panasonic controller (such as the

AJ-A900,

an

 

 

optional accessory).

 

 

 

 

 

 

 

Select 1 (DVCPRO) or 2 (ORIG) if the 23/24 Hz mode

 

 

has been selected by system menu item No.25

 

 

 

(SYSTEM FREQ).

 

 

 

 

 

 

 

 

 

 

204

For selecting whether the RS-232C connector

 

 

is to function.

 

 

 

 

 

 

RS232C SEL

0000

 

 

 

 

OFF

:

The

RS-232C

connector

does

 

 

 

 

 

 

 

 

 

 

 

not function.

 

 

 

0001

 

 

 

ON

: The RS-232C connector functions.

 

 

 

205

For setting the RS-232C data transfer speed

 

 

(baud rate).

 

 

 

 

 

 

BAUD RATE

0000

 

300

 

 

 

 

 

 

 

0001

 

600

 

 

 

 

 

 

 

0002

 

1200

 

 

 

 

 

 

 

0003

 

2400

 

 

 

 

 

 

 

0004

 

4800

 

 

 

 

 

 

 

 

0005

 

9600

 

 

 

 

 

 

 

 

 

206

For setting the RS-232C data length.

 

 

(Unit: bits)

 

 

 

 

 

 

DATA

0000

 

7

 

 

 

 

 

 

LENGTH

 

0001

 

8

 

 

 

 

 

 

 

 

 

207

For setting the number of RS-232C stop bits.

 

 

(Unit: bits)

 

 

 

 

 

 

STOP BIT

 

0000

 

1

 

 

 

 

 

0001

 

2

 

 

 

 

 

 

 

 

208

For setting whether the RS-232C parity bit is

 

to be used and, if it is used, whether even or

PARITY

odd parity is to apply.

 

 

 

 

 

 

0000

 

 

NON

:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The parity bit is not used.

 

 

 

 

0001

 

 

ODD

:

 

 

 

 

 

 

The parity bit is used with an odd parity.

 

 

0002

 

 

EVEN

:

 

 

 

 

 

 

The parity bit is used with an even parity.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The underlining (__) denotes the factory setting mode.

No./Item

 

 

 

Description of setting

 

 

 

 

 

 

 

 

 

 

209

For setting whether or not to return the ACK

 

code when a command is received from RS-

RETURN ACK

232C.

 

 

 

 

 

0000

 

OFF

:

The ACK code is not returned.

 

 

0001

 

ON

:

The ACK code is returned.

 

 

 

 

 

 

212

For selecting the remote control connector

 

for controlling the slave machine when this

MASTER

VTR is to be used as the master machine for

PORT

deck-to-deck operations.

 

 

 

0001

 

IN/OUT

:

The IN/OUT connector is used.

 

0001

 

OUT

:

The OUT connector is used.

 

<Note>

 

 

 

 

 

This setting takes effect only when the 9P button has

 

been set to LOCAL (LED off).

 

 

 

 

 

 

 

 

87

Page 87
Image 87
Panasonic AJ-HD1700 manual Interface