Warning system
When a problem is detected immediately after the power is turned on or during operation, the user is alerted to the trouble by the display window (LCD), WARNING lamp and the lamps inside the viewfinder and also by warning tones heard from the speaker or earphone.
$ SLACKLCD display | OThe SLACK display flashes. |
| OAn error code is displayed where the |
| time code is normally displayed. |
|
|
WARNING lamp | The lamp flashes four times a second. |
|
|
Tally lamp | The lamp flashes four times a second. |
|
|
Warning alarm | The alarm sounds continuously. |
|
|
Viewfinder | The SLACK display flashes. |
|
|
What the warning | The warning points to a problem in the |
indicates | tape |
|
|
VTR unit’s operation | The VTR unit stops. |
| When a solenoid problem has been |
| detected, the power is turned off. |
| (The LCD warning display continues.) |
|
|
Remedial action | Check the error code (see page 107) in |
| the display window, and consult your |
| nearest service center. |
|
|
$ RF
LCD display | The RF display flashes (during recording). |
|
|
WARNING lamp | The lamp flashes four times a second |
| (during recording). |
|
|
Tally lamp | The lamp flashes four times a second |
| (during recording). |
|
|
Warning alarm | The alarm sounds four times a second |
| (during recording). |
|
|
Viewfinder | The RF display comes on (during |
| recording). |
|
|
What the warning | The video heads are clogged. |
indicates | The warning points to a problem in the |
| recording system. |
|
|
VTR unit’s operation | Head clogging is detected, and the alarm |
| tone is sounded. |
| The cleaning roller is activated and the |
| heads are cleaned (for at least 10 |
| seconds). |
| Recording continues but the signals may |
| not be recorded properly. |
| The warning display is held until the rec- |
| pause mode is established. It goes off as |
| soon as the unit is transferred from the |
| |
|
|
Remedial action | Clean the heads. |
| If the signals cannot be recorded properly |
| after cleaning, turn off the power, and |
| consult your nearest service center. |
|
|
LCD display | “00:00:00:11” appears where the time |
| code is normally displayed (for at least 5 |
| seconds during recording). |
|
|
WARNING lamp | The lamp flashes four times a second (for |
| at least 3 seconds during recording). |
|
|
Tally lamp | The lamp flashes four times a second (for |
| at least 3 seconds during recording). |
|
|
Warning alarm | The alarm sounds four times a second |
| (for at least 3 seconds during recording). |
|
|
Viewfinder | The REC WARNING display flashes (for |
| at least 3 seconds during recording). |
|
|
What the warning | The warning points to a problem in the |
indicates | recording control signal. |
|
|
VTR unit’s operation | Recording continues but the signals may |
| not be recorded properly while the |
| warning is displayed. |
|
|
Remedial action | The warning points to a problem with the |
| control signal inside the unit. |
| Consult your nearest service center. |
|
|
LCD display | The SERVO display lights (during |
| recording and playback). |
|
|
WARNING lamp | The lamp flashes four times a second |
| (during recording and playback). |
|
|
Tally lamp | The lamp flashes four times a second |
| (during recording and playback). |
|
|
Warning alarm | The alarm sounds four times a second |
| (during recording and playback). |
|
|
Viewfinder | The SERVO display lights (during |
| recording and playback). |
|
|
What the warning | The servo operation is disturbed. |
indicates |
|
VTR unit’s operation Operation continues but the unit may not
operate properly.
Remedial action Turn off the power, and consult your nearest service center. When tape travel starts, the warning display may flash for a moment and go off: this is normal and not indicative of a malfunction.
105