Setting menu screens (CAM MAIN MENU 4)

INITIALIZE screen

The camera menu settings are initialized and scene files are saved on this screen.

Item

Variable

VF

Remarks

range

display

 

 

 

 

 

 

READ FACTORY

==

ENG

For restoring the camera

DATA

 

 

menu data settings to the

 

 

 

factory settings.

 

 

 

 

WRITE USER

==

ENG

For saving the user’s own

DATA

 

 

camera menu data in the

 

 

 

unit’s memory.

 

 

 

 

SCENE SEL

1

ENG

For designating the

 

:

 

number of the scene file.

 

4

 

 

 

 

 

 

READ

==

ENG

For loading the scene file

 

 

 

whose scene number was

 

 

 

designated.

 

 

 

 

WRITE

==

ENG

For saving data in the

 

 

 

scene file whose scene

 

 

 

number was designated.

 

 

 

 

TITLE 1

==

ENG

For setting the title in

 

 

 

scene file No.1.

 

 

 

 

TITLE 2

==

ENG

For setting the title in

 

 

 

scene file No.2.

 

 

 

 

TITLE 3

==

ENG

For setting the title in

 

 

 

scene file No.3.

 

 

 

 

TITLE 4

==

ENG

For setting the title in

 

 

 

scene file No.4.

 

 

 

 

DIAGNOSTIC screen

The usage statuses and software versions are displayed on this screen.

Item

Variable

VF

Remarks

range

display

 

 

 

 

 

 

CAMSOFT (IN)

==

ENG

For displaying the version

 

 

 

of the software for the

 

 

 

built-in flash memory.

 

 

 

 

CAMSOFT (OUT)

==

ENG

For displaying the version

 

 

 

of the software for the

 

 

 

external flash memory.

 

 

 

 

GAMMA GAIN

==

ENG

For displaying the version

 

 

 

of the gamma table.

 

 

 

 

GAMMA RAM

==

ENG

For displaying the version

 

 

 

of the black gamma table.

 

 

 

 

KNEE

==

ENG

For displaying the version

 

 

 

of the knee table.

 

 

 

 

PLD

==

ENG

For displaying the version

 

 

 

of the software for PLD.

 

 

 

 

EVALUATION screen

The items which are measured for evaluation purposes are set on this screen.

(S/N, MODULATION, RESOLUTION, SENSITIVITY)

SUB menu

VF

Remarks

display

 

 

 

 

 

S/N

ENG

Index for opening the S/N

 

 

measurement screen.

 

 

 

MODULATION

ENG

Index for opening the modulation

 

 

measurement screen.

 

 

 

RESOLUTION

ENG

Index for opening the resolution

 

 

measurement screen.

 

 

 

SENSITIVITY

ENG

Index for opening the sensitivity

 

 

measurement screen.

 

 

 

OPTION screen

The engineer menu display is selected on this screen.

Item

Variable

VF

Remarks

range

display

 

 

 

 

 

 

ENG SECURITY

ON

ENG

For selecting whether to

 

OFF

 

display the engineer

 

 

 

menu.

 

 

 

ON : The engineer menu

 

 

 

is not displayed.

 

 

 

OFF : The engineer menu

 

 

 

is displayed.

 

 

 

 

<Note>

For details on how to release ENG SECURITY, consult your nearest service center.

The underlining in the variable range column indicates the setting in the preset mode.

92