User Data

This unit can save up to five combinations of set values for main menu and screen adjustments made in the picture adjusting menu as user data that can be recalled. You can also return settings and adjustments to their factory defaults.

User data include the following settings.

Menu settings except “SETUP LOAD/SAVE” and “REMOTE in CONTROL” (including button function settings on the monitor front panel)

Screen adjustments made with the picture adjusting knob

Saving user data

1.Press [MENU] to display the main menu.

2.Turn the rotary knob to select the SYSTEM CONFIGmenu and press the rotary knob.

3.Turn the rotary knob to select the SETUP SAVEsub- menu and press the rotary knob.

The setting in the sub menu changes to green.

 

[SYSTEM CONFIG]

 

 

 

 

 

 

SUB WINDOW

 

FULL

 

 

MENU POSITION

CENTER

 

 

STATUS DISPLAY

3SEC OFF

 

 

INPUT NAME SETUP

 

 

 

SETUP LOAD

 

FACTORY

 

 

SETUP SAVE

 

USER1

 

 

 

 

 

 

 

 

 

POWER ON SETUP

 

LAST

 

 

 

 

COLOR SPACE

 

EBU

 

 

 

POWER DOWN

 

OFF

 

 

 

POWER SAVE MODE

 

OFF

 

 

 

CALIBRATION

 

 

 

 

MENU EXIT

SEL.

ENTER

RETURN RETURN

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Changes to green

 

4.Turn the rotary knob to select settings to save from the USER1to USER5and press the rotary knob.

The following screen appears.

[SETUP SAVE]

USER1

YES

NO

MENU EXIT

SEL.

ENTER RETURN RETURN

5.Select “YES” and press the rotary knob. This saves the user data.

6.To return to the previous screen, press [RETURN].

Loading user data

1.Press [MENU] to display the main menu.

2.Turn the rotary knob to select the SYSTEM CONFIGmenu and press the rotary knob.

3.Turn the rotary knob to select the SETUP LOADsub- menu and press the rotary knob.

The setting in the sub menu changes to green.

 

[SYSTEM CONFIG]

 

 

 

 

 

SUB WINDOW

 

FULL

 

MENU POSITION

 

CENTER

 

STATUS DISPLAY

3SEC OFF

 

INPUT NAME SETUP

 

 

 

SETUP LOAD

 

FACTORY

 

 

 

SETUP SAVE

 

USER1

 

 

 

POWER ON SETUP

 

LAST

 

 

COLOR SPACE

 

EBU

 

 

POWER DOWN

 

OFF

 

 

POWER SAVE MODE

 

OFF

 

 

CALIBRATION

 

 

 

MENU EXIT

SEL.

ENTER

 

RETURN RETURN

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Changes to green

4.Turn the rotary knob to select settings to load from the USER1to USER5and press the rotary knob.

The following screen appears.

• To return to the factory default, select “FACTORY.”

[SETUP LOAD]

USER1

YES

NO

MENU EXIT

SEL.

ENTER RETURN RETURN

5.Select “YES” and press the rotary knob. This loads the user data.

6.To return to the previous screen, press [RETURN].

20