Main menu (continued)
Functions displayed during FUNCTION button operation
Pressing any of the [FUNCTION1] to [FUNCTION5] buttons displays the operations assigned to each button as shown below.
•HV DELAY
DELAY OFF/H DELAY/V DELAY/HV DELAY
•BLUE ONLY
BLUE ONLY ON/BLUE ONLY OFF
•GAMMA SELECT
GAMMA STANDARD/GAMMA FILM/ GAMMA STDIO/PST
•SD ASPECT 4:3/16:9
•SCAN
NORMAL SCAN/UNDER SCAN
•SUB WINDOW SINGLE/FULL/PART/STILL
•WFM/VECTOR
WFM/VECTOR OFF/WFM Y ON/WFM R ON/ WFM G ON/WFM B ON/VECTOR×1/VECTOR×2S/ VECTOR×2/VECTOR×4/VECTOR×8
•MARKER
MARKER OFF/4:3 MARKER/ 13:9 MARKER/14:9 MARKER/ CNSCO2.39 MARKER/CNSCO2.35 MARKER/
2:1 MARKER/VISTA MARKER/95 % MARKER/
93 % MARKER/90 % MARKER/88 % MARKER/
80 % MARKER/
xx% MARKER (xx % is a USER setting value of 80 % to 100 %)/
xx%/xx% MARKER (xx % is the VAR setting for 80 to 100 % when set vertical value and horizontal value separately.)/
MARKER ON
•When the setting values of both “16:9” and “4:3” are set to other than “OFF” in the “MARKER” menu settings, the setting value of “16:9” is displayed in the first half section, and the setting value of “4:3” is displayed in the second half section.
•PIXEL TO PIXEL
PIXEL TO PIXEL OFF/PIXEL TO PIXEL CENTER/ PIXEL TO PIXEL LT/PIXEL TO PIXEL RT/ PIXEL TO PIXEL RB/PIXEL TO PIXEL LB
•PIXEL POSITION
PIXEL TO PIXEL CENTER/PIXEL TO PIXEL LT/ PIXEL TO PIXEL RT/PIXEL TO PIXEL RB/ PIXEL TO PIXEL LB
•
•LEVEL METER
METER OFF/METER 2CH/METER 4CH/ METER 8CH
•CROSS HATCH
CROSS HATCH HIGH/CROSS HATCH LOW/ CROSS HATCH OFF
•MONO
MONO ON/MONO OFF
•TIME CODE LTC/VITC/LUB/VUB/TC OFF
•BLACK MODE
BLACK MODE OFF/BLACK MODE ON
•CLOSED CAPTION CC1/CC2/CC3/CC4/CC OFF (SRV1/SRV2/SRV3/SRV4/SRV5/SRV6/CC OFF)
• The displayed items differ depending on the selection for
CC TYPE.
•AUDIO MUTE
AUDIO MUTE OFF/AUDIO MUTE ON
<Note>
WHITE BALANCE is switched to adjustment mode with a FUNCTION button, and the indication that indicates the operation is not displayed.
FUNCTION skip function
This function allows you to skip some of the functions assigned to FUNCTION during FUNCTION operation.
When functions are assigned to [FUNCTION1] to [FUNCTION5] in the FUNCTION menu, a submenu that allows you to skip function settings appears. Turn OFF the setting you want to skip during FUNCTION operation.
Submenus appear for the following functions.
HV DELAY, GAMMA SELECT, WFM, VECTOR, PIXEL POSITION and CROSS HATCH
<<Setup example>>
Select WFM/VECTOR in the FUNCTION menu and press the rotary knob to open the submenu shown below.
1.Turn the rotary knob to select the setting you want to skip and press the rotary knob.
• The set value changes to green.
[WFM/VECTOR SELECT]
WFM Y ON |
| ON | |
WFM R ON |
| ON | |
WFM G ON |
| ON | |
WFM B ON |
| ON | |
VECTOR |
| ON | |
MENU EXIT | SEL. |
| ENTER RETURN RETURN |
|
2.Turn the rotary knob to select OFF and press the rotary knob.
[WFM/VECTOR SELECT]
WFM Y ON |
| OFF | |
WFM R ON |
| ON | |
WFM G ON |
| ON | |
WFM B ON |
| ON | |
VECTOR |
| ON | |
MENU EXIT | SEL. |
| ENTER RETURN RETURN |
|
3.Press RETURN
• The submenu closes and the FUNCTION menu reappears.
33