Main menu (continued)
Equipment required for calibration
•Konica Minolta
•Konica Minolta
•A
Connect the
•Set the Baud rate of the display color analyzer to 38,400.
This unit
Konica Minolta |
|
standard measurement probe | |
(optional accessory) | |
| terminal (9P) |
Konica Minolta | |
(optional accessory) | color analyzer (optional accessory) |
Analyzer Side | (Straight) | On the monitor | ||||||
Pin number | Signal |
|
|
|
|
| Pin number | Signal |
1 | CD |
|
|
|
|
| 1 | N.C. |
2 | RXD |
|
|
|
|
| 2 | TXD |
|
|
|
|
| ||||
3 | TXD |
|
|
|
|
| 3 | RXD |
|
|
|
|
| ||||
4 | DTR |
|
|
|
|
| 4 | DSR |
|
|
|
|
| ||||
5 | GND |
|
|
|
|
| 5 | GND |
|
|
|
|
| ||||
6 | DSR |
|
|
|
|
| 6 | DTR |
|
|
|
|
| ||||
7 | RTS |
|
|
|
|
| 7 | CTS |
|
|
|
|
| ||||
8 | CTS |
|
|
|
|
| 8 | RTS |
|
|
|
|
| ||||
9 | GND |
|
|
|
|
| 9 | N.C. |
•Turn on this unit and perform adequate aging (approx. 1 hour) before starting calibration.
•Make the room dark so that no external light can enter the standard measurement probe before starting the calibration. If external light enters the probe, the low brightness characteristics may not be calibrated correctly.
•LCD panel characteristics and instrument error in the display color analyzer may sometimes result in small differences in values after calibration.
To further fine tune the monitor, set GAIN and BIAS for R, G and B in the VAR mode of COLOR TEMP.
•Do not apply the probe to a WFM/VECTOR display on the screen.
•If you are using
CALIBRATION
Select “CALIBRATION” in the “SYSTEM CONFIG” menu to open the following menus.
Sub menu | Settings | Description |
AUTO CALIBRATION *8 | ▼ | Connect a |
|
| calibration. |
|
| Select “AUTO CALIBRATION” and select “YES” in the confirmation screen that |
|
| appears to start calibration. |
RESET *9 | ▼ | Returns calibration data to their factory defaults. |
|
| Select “RESET” and select “YES” in the confirmation screen that appears to return |
|
| calibrated values to their factory defaults. |
*8 “EXECUTING” is displayed during “AUTO CALIBRATION” and “COMPLETE” appears when calibration ends. “INCOMPLETE” appears if calibration could not be completed.
*9 When “RESET” ends, “COMPLETE” appears.
Performing AUTO CALIBRATION
1.Turn the rotary knob in the “SYSTEM CONFIG” menu to select the “CALIBRATION” submenu and press the rotary knob.
2.Turn the rotary knob to select the AUTO CALIBRATION submenu and press the rotary knob.
[AUTO CALIBRATION]
YES
NO
MENU EXIT | SEL. | ENTER RETURN RETURN |
3.Select “YES” and press the rotary knob. This starts calibration.
[AUTO CALIBRATION]
xxxxxxxxx
MENU EXIT | SEL. | ENTER RETURN RETURN |
xxxxxxxxx indicates that one of the following messages with the meaning listed below appears.
EXECUTING: Operation in progress
COMPLETE: Operation completed
INCOMPLETE: Operation incompleted.
(Check the
4.Turn the power off and then on after performing auto cali- bration.
29