Outdoor Unit CU-4KS31NBU

Indoor unit

Outdoor unit

 

Service valve on

Wide tube

wide tube

DW

O.D.1/2"

 

 

CW

O.D.1/2"

 

 

BW

O.D.3/8"

 

 

AW

O.D.3/8"

 

Header

 

 

Electric

 

Service valve on

expansion

 

valve

 

narrow tube

 

M

Narrow tube

DN

 

O.D.1/4"

 

M

 

CN

 

 

O.D.1/4"

 

M

 

BN

 

 

O.D.1/4"

 

M

 

AN

 

 

O.D.1/4"

Strainer

Header

 

Sub

Main

Compressor

accumulator

accumulator

 

 

High pressure

 

 

switch

 

 

H.P.

 

 

 

Heat exchanger

Cooling cycle

Insulation of Refrigerant Tubing

IMPORTANT

Because capillary tubing is used in the outdoor unit, both the wide and narrow tubes of this air conditioner become cold. To prevent heat loss and wet floors due to dripping of condensation, both tubes must be well insulated with a proper insulation material. The thickness of the insulation should be a min.5/16"(8 mm).

Thickness: Min.5/16"(8 mm)

Insulation

Thickness:

Min.5/16"(8 mm)

After a tube has been insulated, never try to bend it into a narrow

Wide tube

Narrow tube

CAUTION

curve because it can cause the tube to break or crack.

26