Outdoor Unit

: CU-4KS31NBU

 

 

 

 

 

 

 

 

 

Indoor Unit

: CS-MKS9NKU × 4

 

 

 

 

 

 

 

 

 

Power Supply : 230V Single Phase 60Hz

 

 

 

 

 

 

 

 

 

< Cooling Capacity >

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RATING CAPACITY:

30,600 BTU/h

 

AIR FLOW RATE:

1,036 CFM

 

INDOOR

 

 

 

 

 

OUTDOOR

 

 

 

 

 

ENT. TEMP. o F (o C)

 

 

 

AMBIENT TEMP. o F (o C)

 

 

 

WB

 

DB

 

 

65

75

85

 

95

105

115

 

 

 

 

 

 

(18.3)

(23.9)

(29.4)

 

(35.0)

(40.6)

(46.1)

 

 

 

 

 

TC

30,850

29,770

28,590

 

27,980

22,750

16,560

 

 

72

(22.2)

 

SHC

24,260

23,660

23,260

 

22,860

20,440

16,560

 

59

76

(24.4)

 

SHC

27,890

27,280

26,680

 

26,480

22,750

16,560

 

(15.0)

80

(26.7)

 

SHC

30,850

29,770

28,590

 

27,980

22,750

16,560

 

 

84

(28.9)

 

SHC

30,850

29,770

28,590

 

27,980

22,750

16,560

 

 

88

(31.1)

 

SHC

30,850

29,770

28,590

 

27,980

22,750

16,560

 

 

 

 

 

TC

32,150

31,030

29,820

 

29,290

23,300

16,930

 

 

72

(22.2)

 

SHC

20,040

19,640

19,030

 

18,830

16,420

13,800

 

63

76

(24.4)

 

SHC

23,660

23,260

22,660

 

22,450

19,840

16,930

 

(17.2)

80

(26.7)

 

SHC

27,480

26,880

26,480

 

26,080

23,300

16,930

 

 

84

(28.9)

 

SHC

30,900

30,500

29,820

 

29,290

23,300

16,930

 

 

88

(31.1)

 

SHC

32,150

31,030

29,820

 

29,290

23,300

16,930

 

 

 

 

 

TC

33,410

32,280

31,030

 

#

30,600

23,790

17,260

 

 

72

(22.2)

 

SHC

15,820

15,410

15,010

 

14,810

12,200

9,780

 

67

76

(24.4)

 

SHC

19,440

19,030

18,430

 

18,430

15,820

13,400

 

(19.4)

80

(26.7)

 

SHC

23,260

22,660

22,250

 

22,050

19,440

17,020

 

 

84

(28.9)

 

SHC

26,680

26,280

25,870

 

25,670

23,060

17,260

 

 

88

(31.1)

 

SHC

30,300

29,900

29,290

 

29,290

23,790

17,260

 

 

 

 

 

TC

34,630

33,470

32,190

 

31,890

24,200

17,520

 

 

72

(22.2)

 

SHC

11,390

10,990

10,590

 

10,380

7,770

5,560

 

71

76

(24.4)

 

SHC

15,010

14,610

14,210

 

14,010

11,390

9,180

 

(21.7)

80

(26.7)

 

SHC

18,830

18,230

17,830

 

17,830

15,010

13,000

 

 

84

(28.9)

 

SHC

22,250

21,850

21,450

 

21,250

18,630

16,420

 

 

88

(31.1)

 

SHC

25,870

25,470

25,070

 

24,870

22,250

17,520

 

 

 

 

 

TC

35,630

34,460

33,160

 

33,010

24,460

17,680

 

75

76

(24.4)

 

SHC

10,790

10,380

9,980

 

9,780

7,170

5,150

 

(23.9)

80

(26.7)

 

SHC

14,410

14,010

13,600

 

13,600

10,990

8,980

 

 

84

(28.9)

 

SHC

18,030

17,630

17,220

 

17,220

14,410

12,400

 

 

88

(31.1)

 

SHC

21,650

21,250

20,840

 

20,640

18,030

16,020

TC : Total Cooling Capacity (BTU/h) SHC : Sensible Heat Capacity (BTU/h)

NOTE

1.Rating conditions (#) : Indoor Unit Entering Air Temp. 80 °F (26.7 °C) DB / 67 °F (19.4 °C) WB

:Outdoor Ambient Temp. 95 °F (35 °C) DB

2.Above data does not take Freeze Prevention Protection during cooling operation into account. For this reason, the value may vary from the actual cooling characteristics.

3.Above data represents the value when the operation frequency of a compressor is fixed.