Panasonic CU-4KS31NBU service manual CU-4KS24NBU, CS-KS18NB4UW+ CS-MKS12NB4U+ CS-MKS12NB4U

Models: CU-4KS31NBU

1 114
Download 114 pages 23.14 Kb
Page 53
Image 53
: CS-KS18NB4UW + CS-MKS12NB4U + CS-MKS12NB4U

Outdoor Unit

: CU-4KS24NBU

 

 

 

 

 

 

 

 

 

Indoor Unit

: CS-KS18NB4UW + CS-MKS12NB4U + CS-MKS12NB4U

 

 

Power Supply : 230V Single Phase 60Hz

 

 

 

 

 

 

 

 

 

< Cooling Capacity >

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RATING CAPACITY:

24,800 BTU/h

 

AIR FLOW RATE:

812 CFM

 

INDOOR

 

 

 

 

OUTDOOR

 

 

 

 

 

ENT. TEMP. o F (o C)

 

 

AMBIENT TEMP. o F (o C)

 

 

 

WB

 

DB

 

65

75

85

 

95

105

115

 

 

 

 

 

(18.3)

(23.9)

(29.4)

 

(35.0)

(40.6)

(46.1)

 

 

 

 

TC

25,120

24,260

23,340

 

22,720

18,300

13,510

 

 

72

(22.2)

SHC

19,520

19,040

18,570

 

18,410

16,360

13,510

 

59

76

(24.4)

SHC

22,360

21,880

21,410

 

21,100

18,300

13,510

 

(15.0)

80

(26.7)

SHC

25,120

24,260

23,340

 

22,720

18,300

13,510

 

 

84

(28.9)

SHC

25,120

24,260

23,340

 

22,720

18,300

13,510

 

 

88

(31.1)

SHC

25,120

24,260

23,340

 

22,720

18,300

13,510

 

 

 

 

TC

26,160

25,290

24,340

 

23,760

18,710

13,790

 

 

72

(22.2)

SHC

16,210

15,890

15,420

 

15,260

13,050

11,160

 

63

76

(24.4)

SHC

19,040

18,730

18,260

 

17,940

15,890

13,790

 

(17.2)

80

(26.7)

SHC

21,880

21,570

21,100

 

20,940

18,710

13,790

 

 

84

(28.9)

SHC

24,720

24,410

23,930

 

23,620

18,710

13,790

 

 

88

(31.1)

SHC

26,160

25,290

24,340

 

23,760

18,710

13,790

 

 

 

 

TC

27,180

26,290

25,320

 

#

24,800

19,070

14,020

 

 

72

(22.2)

SHC

12,890

12,580

12,260

 

11,950

9,740

8,000

 

67

76

(24.4)

SHC

15,730

15,420

14,940

 

14,790

12,580

10,690

 

(19.4)

80

(26.7)

SHC

18,730

18,260

17,940

 

17,630

15,420

13,680

 

 

84

(28.9)

SHC

21,410

21,100

20,620

 

20,460

18,260

14,020

 

 

88

(31.1)

SHC

24,250

23,780

23,460

 

23,300

19,070

14,020

 

 

 

 

TC

28,150

27,250

26,260

 

25,820

19,350

14,210

 

 

72

(22.2)

SHC

9,420

9,110

8,790

 

8,630

6,430

4,690

 

71

76

(24.4)

SHC

12,260

11,950

11,470

 

11,320

9,110

7,530

 

(21.7)

80

(26.7)

SHC

15,100

14,790

14,470

 

14,310

12,100

10,370

 

 

84

(28.9)

SHC

17,940

17,630

17,310

 

17,150

14,790

13,210

 

 

88

(31.1)

SHC

20,780

20,310

19,990

 

19,830

17,630

14,210

 

 

 

 

TC

28,950

28,050

27,050

 

26,320

19,520

14,320

 

75

76

(24.4)

SHC

8,790

8,480

8,160

 

8,000

5,800

4,380

 

(23.9)

80

(26.7)

SHC

11,790

11,470

11,160

 

10,840

8,790

7,220

 

 

84

(28.9)

SHC

14,470

14,310

13,840

 

13,680

11,470

10,050

 

 

88

(31.1)

SHC

17,310

16,990

16,680

 

16,520

14,310

12,740

TC : Total Cooling Capacity (BTU/h) SHC : Sensible Heat Capacity (BTU/h)

NOTE

1.Rating conditions (#) : Indoor Unit Entering Air Temp. 80 °F (26.7 °C) DB / 67 °F (19.4 °C) WB

:Outdoor Ambient Temp. 95 °F (35 °C) DB

2.Above data does not take Freeze Prevention Protection during cooling operation into account. For this reason, the value may vary from the actual cooling characteristics.

3.Above data represents the value when the operation frequency of a compressor is fixed.

53

Page 53
Image 53
Panasonic CU-4KS31NBU service manual CU-4KS24NBU, CS-KS18NB4UW+ CS-MKS12NB4U+ CS-MKS12NB4U