5-1-3. Temperature Charts (CU-4KS31NBU)

5-1-3. Temperature Charts (CU-4KS31NBU)

Outdoor Unit CU-4KS31NBUIndoor Unit CS-MKS7NKU 1

Outdoor Unit CU-4KS31NBUIndoor Unit CS-MKS7NKU 1 Cooling Characteristics

(RH : 46%, Indoor fan speed : High fan) (230V, 60Hz)

(1) Low pressure performance chart

servicevalve

psig(MPaG)

174

Lo fan

Hi fan

Hi fan

HH fan

(1.2)

 

 

 

 

 

 

 

 

 

tube

 

146

 

 

. 86°F (30°C)

wide

 

(1.0)

 

 

 

 

Indoor

air temp

 

 

 

 

 

 

 

 

 

 

80°F

(27°C)

at

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(24°C)

Low pressure

 

 

 

 

75°F

 

118

 

 

 

 

 

 

 

 

 

(0.8)

 

 

 

 

 

 

 

 

 

 

 

 

90

 

 

 

 

 

 

(0.6)77

 

86

95

104

 

 

(25)

 

(30)

(35)

(40)

Outdoor air temperature °F (°C)

(2) Operating current performance chart

 

5

 

 

 

 

 

 

 

 

Lo fan

Hi fan

 

Hi fan

 

HH fan

(A)

 

 

 

 

 

 

(27°C)

current

 

 

 

 

(30°C)

 

 

 

 

.86°F

80°F

 

(24°C)

 

 

 

 

 

 

 

 

 

75°F

4

 

 

 

 

 

 

temp

 

 

Operating

 

 

 

 

 

 

 

 

air

 

 

 

 

 

Indoor

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

86

 

95

 

 

104

 

77

 

 

 

 

(25)

(30)

 

(35)

 

 

(40)

Outdoor air temperature °F (°C)

(3) Indoor discharge air performance chart

°F(°C)

 

Lo fan

Hi fan

 

Hi fan

HH fan

 

 

 

 

 

 

temperature

68.0(20)

 

 

 

 

64.4(18)

 

 

 

 

60.8(16)

 

 

. 86°F

(30°C)

air

 

 

 

 

Indoor

air

temp

 

discharge

57.2(14)

 

80°F (27°C)

 

 

53.6(12)

 

 

75°F (24°C)

 

 

 

 

 

 

Indoor

50.0(10)

 

 

 

 

46.4(

8)

 

 

 

 

 

 

 

 

 

 

 

77

86

 

95

104

 

 

(25)

(30)

 

(35)

(40)

Outdoor air temperature °F (°C)

NOTE

This performance chart shows operation of a single wall-mounted indoor unit. The performance chart will vary depending on the indoor unit type.

Check each performance value in test-run mode. Electrical performance values represent a combined indoor/outdoor value. (In this case, be sure to stop all the indoor units where performance is not being checked.)

The performance is for a tubing length of 24.6ft (7.5m). If the tubing length is different, the performance chart will vary.