Panasonic CU-4KS31NBU Cooling Capacity, Outdoor Unit : CU-3KS19NBU, Indoor Unit : CS-MKS9NKU×

Models: CU-4KS31NBU

1 114
Download 114 pages 23.14 Kb
Page 50
Image 50
5-2. Cooling Capacity

5-2. Cooling Capacity

Outdoor Unit : CU-3KS19NBU

Indoor Unit : CS-MKS9NKU × 3

Power Supply : 230V Single Phase 60Hz

< Cooling Capacity >

RATING CAPACITY:

18,800 BTU/h

 

AIR FLOW RATE:

777 CFM

INDOOR

 

 

 

 

OUTDOOR

 

 

 

 

ENT. TEMP. o F (o C)

 

 

AMBIENT TEMP. o F (o C)

 

 

WB

 

DB

 

65

75

85

 

95

105

115

 

 

 

 

(18.3)

(23.9)

(29.4)

 

(35.0)

(40.6)

(46.1)

 

 

 

TC

18,880

18,230

17,540

 

16,990

16,170

15,290

 

72

(22.2)

SHC

16,240

15,940

15,630

 

15,330

15,030

14,580

59

76

(24.4)

SHC

18,800

18,230

17,540

 

16,990

16,170

15,290

(15.0)

80

(26.7)

SHC

18,880

18,230

17,540

 

16,990

16,170

15,290

 

84

(28.9)

SHC

18,880

18,230

17,540

 

16,990

16,170

15,290

 

88

(31.1)

SHC

18,880

18,230

17,540

 

16,990

16,170

15,290

 

 

 

TC

19,800

19,130

18,420

 

17,880

17,030

16,120

 

72

(22.2)

SHC

13,220

12,920

12,620

 

12,470

12,010

11,710

63

76

(24.4)

SHC

15,940

15,630

15,330

 

15,030

14,730

14,430

(17.2)

80

(26.7)

SHC

18,650

18,350

18,050

 

17,880

17,030

16,120

 

84

(28.9)

SHC

19,800

19,130

18,420

 

17,880

17,030

16,120

 

88

(31.1)

SHC

19,800

19,130

18,420

 

17,880

17,030

16,120

 

 

 

TC

20,730

20,050

19,320

 

#

18,800

17,920

16,970

 

72

(22.2)

SHC

10,200

9,900

9,750

 

9,450

9,150

8,840

67

76

(24.4)

SHC

12,920

12,620

12,310

 

12,160

11,860

11,560

(19.4)

80

(26.7)

SHC

15,630

15,480

15,180

 

15,030

14,580

14,280

 

84

(28.9)

SHC

18,350

18,050

17,900

 

17,600

17,290

16,970

 

88

(31.1)

SHC

20,730

20,050

19,320

 

18,800

17,920

16,970

 

 

 

TC

21,650

20,970

20,220

 

19,730

18,830

17,850

 

72

(22.2)

SHC

7,030

6,880

6,580

 

6,430

6,130

5,830

71

76

(24.4)

SHC

9,750

9,450

9,300

 

9,000

8,690

8,390

(21.7)

80

(26.7)

SHC

12,470

12,310

12,010

 

11,860

11,560

11,260

 

84

(28.9)

SHC

15,180

15,030

14,730

 

14,580

14,280

13,970

 

88

(31.1)

SHC

17,900

17,600

17,440

 

17,140

16,840

16,540

 

 

 

TC

22,470

21,780

21,020

 

20,570

19,650

18,620

75

76

(24.4)

SHC

6,580

6,430

6,280

 

6,130

5,830

5,530

(23.9)

80

(26.7)

SHC

9,450

9,300

9,000

 

8,840

8,540

8,240

 

84

(28.9)

SHC

12,160

11,860

11,710

 

11,560

11,260

10,960

 

88

(31.1)

SHC

14,880

14,580

14,430

 

14,280

13,970

13,670

TC : Total Cooling Capacity (BTU/h) SHC : Sensible Heat Capacity (BTU/h)

NOTE

1.Rating conditions (#) : Indoor Unit Entering Air Temp. 80 °F (26.7 °C) DB / 67 °F (19.4 °C) WB

:Outdoor Ambient Temp. 95 °F (35 °C) DB

2.Above data does not take Freeze Prevention Protection during cooling operation into account. For this reason, the value may vary from the actual cooling characteristics.

3.Above data represents the value when the operation frequency of a compressor is fixed.

50

Page 50
Image 50
Panasonic CU-4KS31NBU service manual Outdoor Unit : CU-3KS19NBU, Indoor Unit : CS-MKS9NKU×, < Cooling Capacity >