3-5 I/O Connection Diagram

3-5 I/O Connection Diagram

3

3-5-1 Connection to PLC output unit

Connection to the Mitsubishi© PLC AY51 output unit

I/O INTERFACE

AY51 type output unit

RR

R

SRCP series controller

Y00

 

I/O. CN

 

TB 1

DI 0

 

 

A5

Y01

 

2

DI 1

Y02

 

B5

 

3

DI 2

Y03

 

A6

 

4

DI 3

Y04

 

B6

 

5

DI 4

Y05

 

A7

 

6

DI 5

Y06

 

B7

 

7

DI 6

Y07

 

A8

 

8

DI 7

Y08

 

B8

 

9

 

Y09

 

10

 

Y0A

 

11

 

Y0B

 

12

 

Y0C

 

13

 

Y0D

 

14

 

Y0E

 

15

 

Y0F

 

16

 

DC24V

17

 

0V

 

18

 

Y10

 

19

LOCK

Y11

 

B4

 

20

SERVO

 

 

A4

Y12

 

21

RESET

 

 

B3

Y13

 

22

ORG-S

 

 

A3

Y14

 

23

STEP-R

Y15

 

B2

 

24

AUTO-R

Y16

 

A2

 

25

INC-PT

Y17

 

B1

 

26

ABS-PT

 

 

A1

Y18

 

27

 

 

 

EXT. CN

 

 

1

EMG 1

 

 

2

EMG 2

DC24V

35

 

0V

 

3

24V

 

36

24G

 

 

4

+ -

FG

External DC 24V power supply

3-12