3)After the emergency stop is released, a mes- sage appears asking whether to turn the servo on.

To turn the servo on, press F1 (yes). To leave the servo off , press F2 (no).

4)Then, another message appears asking if ready to operate.

To restart operation, press F1 (yes). To cancel restarting, press F2 (no).

5)Operation starts when F1 (yes) was pressed in step 4.

If F2 (no) was pressed, the screen returns to step 1.

9-5 Emergency Stop Function

[OPRT-STEP] 100 0: 7 servo on ready ?

1yes 2no

[OPRT-STEP] 100 0: 7 continue OK ?

1yes 2no

[OPRT-STEP] 100 0: 7 001:MOVA 254,100

[ 0.00] 1SPD 2RSET3CHG 4next

c CAUTION

When the SERVICE mode function is enabled, the following safety control will function. (See "10-4 SERVICE mode function".)

• If the hold-to-run function is enabled, the robot stops upon releasing F1 (yes) in step 4 in "SERVICE mode state".

9

OPERATING THE

ROBOT

9-11

Page 143
Image 143
Yamaha SRCP manual Robot