11-5 Communication Command Description

(5)@SDEL <program number>,<step number>

Deletes a specified step.

Program number

: This is a number used to identify each program and can be from 0

 

to 99.

 

Step number

: This is a number used to identify each step and can be from 1 to

 

255.

 

Transmission example

: @SDEL 31,99 c/r l/f

Deletes step 99 of program

 

 

No. 31.

Response example 1

: OK c/r l/f

 

Response example 2

: NG c/r l/f

The specified step number is

 

42: cannot find step c/r l/f

not registered.

(6)@SMOD <program number>,<step number>

Modifies data in a specified step. The SRCP controller will transmit READY when this command is received. Confirm that READY is received and then transmit the modification data.

Program number

: This is a number used to identify each program and can be from 0

 

 

to 99.

 

Step number

: This is a number used to identify each step and can be from 1 to

 

 

255.

 

Transmission example 1 :

Send

Receive

 

 

@SMOD 0,5 c/r l/f

 

 

 

 

READY c/r l/f

 

 

TIMR 50 c/r l/f

 

 

 

 

OK c/r l/f

Transmission example 2 :

Send

Receive

 

 

@SMOD 0,5 c/r l/f

 

 

 

 

NG c/r l/f

 

 

 

43: cannot find PGM c/r l/f

(7)@COPY <program number (copy source)>,<program number (copy destination)>

Copies a program. If a program exists in the copy destination, the program will be rewritten.

Program number

: This is a number used to identify each program and can be from 0

 

to 99.

 

Transmission example

: @COPY 0,1 c/r l/f

Copies program No. 0 to

 

 

program No. 1.

Response example 1

: OK c/r l/f

 

Response example 2

: NG c/r l/f

The program to be copied is

 

43: cannot find PGM c/r l/f

not registered.