3-6 I/O Control Timing Charts

3-6-4 When emergency stop is input

Emergency stop

EMG

Dedicated command

BUSY

END

READY

5ms or less 1ms or less

The READY signal turns off. The BUSY signal also turns off while a dedicated command is being executed. The END signal remains unchanged.

To enable robot operation, cancel emergency stop to turn on the READY signal, then input the servo recovery command (SERVO).

3-6-5 When alarm is issued

Alarm

Dedicated command

BUSY

END

READY

5ms or less 1ms or less

The READY, BUSY and END signals all turn off.

Correct the problem while referring to "13-2 Alarm and Countermeasures".